Problem
Possible Cause
Corrective Action
No display on LCD (screen is blank).
No power to unit.
Check the connection to the pump
timer (see Section 3.4).
Problem
Possible Cause
Corrective Action
Flow light is on (Display says “No Flow”).
Caused by insufficient water flow through
the cell.
NOTE:
When the Flow light is on,
the chlorine output will be
turned off.
Filter is dirty.
Clean the filter.
Closed valves.
Check and correct all valve
alignments.
Pump fails to provide
sufficient water flow.
Check for correct operation of the
pump. Ensure there is no loss of
pump prime or clogged strainer
baskets.
Problem
Possible Cause
Corrective Action
Salt light is on (Display says “Check Salt”).
NOTE:
The Salt light will turn on
when the salt level drops
below 3,000 ppm and it will
remain on until the salt level is
raised above 3,500 ppm.
Salt level is less than 3,000
ppm, depending on water
temperature.
Maintain a salinity level of
4,000 ppm - 4,500 ppm
(see Section 4.7 or contact
your local pool professional).
A combination of extremely
low water temperature (close
to freezing) and low salt level
(~3,500 ppm).
Maintain a salinity level of
4,000 ppm - 4,500 ppm
(see Section 4.7 or contact
your local pool professional).
Cell life expired.
Replace the cell.
Problem
Possible Cause
Corrective Action
“Output Fault” appears on the screen.
Power supply.
Turn the power off to the power pack
and consult your local pool care
professional.