WARNING
FOR YOUR SAFETY:
This product must be installed and serviced by a professional pool/spa service technician.
The procedures in this manual must be followed exactly. Failure to follow warning notices and instructions may
result in property damage, serious injury, or death. Improper installation and/or operation will void the warranty.
When using electrical products, basic precautions should always be followed, including the following:
• DANGER: RISK OF ELECTRIC SHOCK WHICH CAN RESULT IN SERIOUS INJURY OR DEATH. Before
attempting installation or service, ensure that all power to the device is disconnected/turned off at the circuit
breaker. Connect only to a circuit protected by a ground-fault circuit-interrupter (GFCI).
• Grounding is required. The unit should be serviced by a qualified service representative and should be
properly grounded. (See Section 3.5, Earth Grounding).
• Install to permit access for servicing.
• Please read all cautions and safety instructions in the Important Safety Instructions section.
Before
attempting any electrical wiring, be sure to read and follow safety instructions. Wiring should only be
attempted by a qualified professional.
3.6 Connection to an AquaLink® RS Control System or PDA (Optional)
The Jandy® AquaLink RS or PDA is a multi-function pool controller which can fully control the function of the
Jandy AquaPure® Ei chlorine generating device. Adjustment of the chlorine production rate can be controlled from
the main menu of the Jandy AquaLink RS or PDA. The AquaLink RS or PDA offers individual pool and spa settings
for output percentage. Refer to the AquaLink RS or PDA Owner’s Manual for more information.
NOTE
The Jandy AquaPure Ei chlorine generating device will communicate with all AquaLink models Rev. K or later.
3.6.1 Setting the Controller Type on the Power Pack
Before wiring to the AquaLink RS Control System, the controller type must be set on the power pack to allow
communication between the power pack and the AquaLink RS Control System or PDA. The default controller type
setting is Jandy L/M.
NOTE:
The controller type must be set before making the wiring connection between the power pack and the
AquaLink otherwise the power pack may be locked out of the AquaLink.
To set the controller type:
1. Turn the power pack on by pressing the ON/OFF button.
2. Wait for the start-up sequence to complete.
3. Press and hold the OUTPUT button for approximately four (4) seconds. After four (4) seconds, a controller type
will be displayed on the screen.
4. Keep the OUTPUT button pressed to toggle through the list of controllers. Each controller will be displayed on
the screen for two (2) seconds.
5. Release the OUTPUT button when the desired controller is displayed. To connect to the Aqualink RS Control
System or PDA, select the JANDY L/M controller type.
3.6.2 Wiring to the AquaLink RS Control System or PDA
1. Ensure that all power to the power pack and the controller is disconnected/turned off at the circuit breaker.
2. Remove the screws attaching the cover to the back plate and prop the cover up to expose the terminals
(see Figure 19).
NOTE:
Be carefully not to pull the ribbon cable that is connected to the Power Supply and the Cover.