Jandy APURE35 Скачать руководство пользователя страница 10

Page 10

Section 3. 

Installation Instructions

Before you begin your installation, please check that you have the right tools and a suitable location to install the 

power pack and cell.  Please ensure that you have read and understood the Important Safety Instructions section. 

3.1  Materials and Tools

Installation Materials Furnished

Tools Needed for Installation

•  Pipe Spacer - for 1½ in. (40 mm) pipe
•  Hole Saw
•  Screw Set (includes wall plugs)
•  Installation and Operation Manual

•  Cordless Drill (or Power Drill)
•  15/64 in. (6 mm) Hammer Drill Bit (only necessary to drill into 

brick or concrete)

•  Pencil or Marking Pen
•  Phillips Head Screwdriver or Phillips Head Drill Bit

  WARNING

EQUIPMENT UNDER PRESSURE: 

 Always turn pump off prior to installing or servicing the Jandy® AquaPure® 

Ei chlorine generating device. Your pump/filter system is operated under pressure and the pressure must be 

released before you begin work. Please see your pump/filter owner’s manual for further instructions. 

  WARNING

The Jandy AquaPure Ei chlorine generating device must be installed 

horizontally with the cell above the pipe to avoid buildup of flammable 

gases which can result in FIRE OR EXPLOSION. 

Figure 3. 

Installation Requirements

15 ft. (4.6 m) MAX

Cell

Power 

Pack

⅓ ft. (0.38m) MIN

3.2  Installation Requirements

WARNING

FOR YOUR SAFETY: 

 This product must be installed and serviced by a professional pool/spa service technician. 

The procedures in this manual must be followed exactly. Failure to follow warning notices and instructions may 

result in property damage, serious injury, or death.  Improper installation and/or operation will void the warranty. 

The installation requirements for the Jandy AquaPure Ei chlorine 

generating device are as follows: 

• 

The power pack must be be installed at least 5 ft. (1.5 m) vertically off 

the ground.

•  In the US, 

the power pack must be be installed at least 5 ft. (1.5 m) from 

the inside wall of your swimming pool or spa;  in Canada, the power 

pack must be be installed at least 10 ft. (3 m) from the inside wall of your 

swimming pool or spa.

•  The cell must be installed on a 1 ⅓ ft. (0.4 m) horizontal length 

of pipe after the heaters, pumps, and filters, as the last piece of 

equipment in the circulation plumbing system just before the pool (see 

Figure 3).  

•  The cell must be installed no more than 15 ft. (4.6 m)

 from the power 

pack (see Figure 3).

Содержание APURE35

Страница 1: ...nstallation and service Improper installation and or operation can create an unwanted electrical hazard which can cause serious injury property damage or death Improper installation and or operation w...

Страница 2: ...Page 2...

Страница 3: ...l 18 4 2 Determining Pool Size Litres of Water in Your Pool 18 4 3 Selecting Model Size 18 4 4 Chemistry You Need to Know 18 4 5 Optimum Pool Water Conditions 19 4 6 Chlorine Testing 20 4 7 Salt NaCl...

Страница 4: ...ment 12 Figure 14 Locking Ring 12 Figure 15 Locking Ring Level 12 Figure 16 Connecting Cell Leads 12 Figure 17 Attaching Terminal Cap 12 Figure 18 240 VAC or 120 VAC Wiring Diagram 13 Figure 19 Access...

Страница 5: ...NING To reduce the risk of electric shock fire or injury service should only be attempted by a qualified pool service professional WARNING Installation must be done in accordance with the National Ele...

Страница 6: ...mmersion in hot water may induce hyperthermia Hyperthermia occurs when the internal temperature of the body reaches a level several degrees above the normal body temperature of 98 6 F 37 C The symptom...

Страница 7: ...und your pool and or spa please discuss all options with your contractor to assess the compatibility of such materials and chemicals When mixing acid with water ALWAYS ADD ACID TO WATER NEVER ADD WATE...

Страница 8: ...35 000 gal 132 000 L Output Current adjustable by switch APURE35 5A DC Chlorine Output APURE35 0 62 oz 17 5 g per hour Dimensions Power Pack L x W x H 10 in x 4 5 in x 13 in Electrolytic Cell L x W x...

Страница 9: ...120V APURE25 APURE35 FOR YOUR SAFETY This product must be installed and serviced by professionals who are quali ed in pool spa product installation and service Improper installation and or operation...

Страница 10: ...h the cell above the pipe to avoid buildup of flammable gases which can result in FIRE OR EXPLOSION Figure 3 Installation Requirements 15 ft 4 6 m MAX Cell Power Pack 1 ft 0 38m MIN 3 2 Installation R...

Страница 11: ...MAX Spacer used for 1 in 40mm pipe only 1 Ensure placement of the cell and the power pack will meet all the installation requirements outlined in Section 3 2 2 Screw the power pack bracket into posit...

Страница 12: ...2 Insert the o ring into the channel on the clamp and then attach the cell see Figure 11 and 12 13 Position the locking ring in proper alignment making sure the bump aligns with the top thread see Fig...

Страница 13: ...to the common approved earth bonding point Never ground a pool pump to the chassis backplate In Canada the Canadian Electrical Code CEC dictates that the bonding conductor be minimum 6 AWG 13 3 mm2 WA...

Страница 14: ...or PDA The AquaLink RS or PDA offers individual pool and spa settings for output percentage Refer to the AquaLink RS or PDA Owner s Manual for more information NOTE The Jandy AquaPure Ei chlorine gen...

Страница 15: ...o the Power PCB 6 In the AquaLink RS or PDA power center wire the power pack directly to the LOAD SIDE of the filter pump relay see Figure 20 Figure 20 Wiring Power Pack to an AquaLink RS or PDA Power...

Страница 16: ...ing connections see Section 3 6 2 and the controller setting on the power pack see Section 3 6 1 Figure 21 Communication Wiring between Power Pack and AquaLink RS Control System or PDA Network Jandy P...

Страница 17: ...tion Figure 23 Example of Alternative Installation 3 8 Alternative Installation When Pipe is Obstructed If the only suitable length of pipe is obstructed such as on a multiport valve often found on a...

Страница 18: ...ear round use and high water temperatures such as Florida Texas Arizona Las Vegas and Southern California the following must be considered Year Round Use Up sizing the Jandy AquaPure Ei chlorine gener...

Страница 19: ...H rises above 7 6 have a pool professional test to see if other factors such as high calcium hardness or total alkalinity are the cause and then balance accordingly Total Dissolved Solids TDS Adding s...

Страница 20: ...t can shorten the life of the unit CAUTION It is important to note that certain materials used in and around swimming pools and spas may not be compatible with chemicals commonly used to purify pool a...

Страница 21: ...cular pool For vinyl and fiberglass pools salt can be added at start up Table 1 Approximate Pounds and Kilograms of Salt Needed to Obtain 4 0 gpl 4 000 ppm Current Salt Level ppm Pool Spa Size US Gall...

Страница 22: ...kgs 6 3 lbs 2 9 kgs 7 6 lbs 3 4 kgs 8 9 lbs 4 0 kgs 30 1 7 lbs 0 8 kgs 2 5 lbs 1 2 kgs 3 4 lbs 1 5 kgs 4 2 lbs 1 9 kgs 5 1 lbs 2 3 kgs 5 9 lbs 2 7 kgs 40 0 8 lbs 0 4 kgs 1 3 lbs 0 6 kgs 1 7 lbs 0 8 k...

Страница 23: ...etting the chlorine output level you must consider the size of the pool the amount of use the pool will be receiving and how hot the weather is All these factors weigh greatly on the level of output n...

Страница 24: ...e automated cell cleaning feature During the transition between changing its polarity there is a five 5 minute wait time when the cell will not produce any chlorine Once it has changed polarity it wil...

Страница 25: ...t pool water for calcium hardness level using test kit or by having a water sample tested by a pool professional Adjust as necessary to maintain a calcium hardness of 175 400 ppm see Section 4 4 6 2 M...

Страница 26: ...it is observed that there is excessive scale formation between the plates or debris is present the cell must be cleaned as follows 1 Ensure that all power to the power pack and the controller is disc...

Страница 27: ...e CHLORINE PRODUCTION down to 10 20 Otherwise chlorine production will exceed the recommended level of 1 3 ppm 6 4 1 Winterizing Procedure Figure 28 Winterizing Cap Installed Figure 29 Locking Ring Le...

Страница 28: ...ity meter or another realiable method to test the salinity of the pool water Once the existing salinity has been established use Table 1 in section 4 7 4 to determine the amount of salt to add to reac...

Страница 29: ...m Possible Cause Corrective Action Salt light is on Display says Check Salt NOTE The Salt light will turn on when the salt level drops below 3 000 ppm and it will remain on until the salt level is rai...

Страница 30: ...ramines combined chlorine Manually shock the pool see Section 4 4 Problem Possible Cause Corrective Action Cloudy water slimy walls of pool Combined algae and bacteria growth Brush down the affected w...

Страница 31: ...Clamp Assy APURE Ei R0511700 Power Pack 6 R Kit Power PCB Assy APURE 35 R0512200 7 R Kit Control PCB Assy APURE Ei R0512300 8 R Kit Cover Assy Controller APURE Ei R0512400 9 R Kit Output Cable Assy A...

Страница 32: ...2 3 2 3 4 5 13 5 5 5 5 Figure 29 Cell Exploded View Figure 30 Winterizing Cap and Locking Ring Tool Out put Flow On Off Salt 6 7 8 8 8 7 10 8 11 9 9 Figure 31 Power Pack Exploded View 8 2 Exploded Vi...

Страница 33: ...Page 33 NOTES...

Страница 34: ...Page 34 NOTES...

Страница 35: ...Page 35 NOTES...

Страница 36: ...0 Commerce Way Vista CA 92081 Tel 800 822 7933 Fax 877 327 1403 For warranty support in Canada Zodiac Pool Systems Canada Inc 2115 South Service Road West Unit 3 Oakville Ontario Canada L6L 5W2 Tel 88...

Отзывы: