Test and Configuration Settings
7-3
Revision 2 - 26 April, 2000
HP SERIES DIMMER
TECHNICAL MANUAL
The DIP switch is checked at startup and the dimmer configured accordingly. The status
of the DIP switch is indicated in the software version – this is accessed by holding down
the “Normal” button for 2 seconds when “OK” is displayed. The following table
indicates the displayed version for the various DIP switch combinations:
Switch #2 Switch #1 Displayed Version
Off
Off
V2.2A/0x 06-SEP-99 350
Off
On
V2.2A/0x 06-SEP-99 800
On
Off
V2.2A/0x 06-SEP-99 1600
On
On
V2.2A/0x 06-SEP-99 2400
7.4
Dimmer Re-calibration
After completing repairs on the HP dimmer it is advisable to re-calibrate the output
voltage. Refer to section 4.1.4.8 for details.