JD-N2
USER’S GUIDE
JD-N2
Section C-25
Manual Operation
This parameter is used to override the controller’s calculated demands and
move the curtain in a given direction. If this parameter is set to
Auto
(Auto), the curtain will follow the demand the controller has calculated
according to temperature readings. If this parameter is set to
Hold
(Hold),
the curtain will not move. If this parameter is set to
Open
(Open), the
curtain will open continuously. If this parameter is set to
Close
(Close), the
curtain will close continuously.
Other
Differential
Set 1
This parameter sets the relative temperature at which the curtain will follow
it’s timer and either open or close. When
Room Temperature
is equal to or
below
Target Temperature
–
Differential
, it will close according to
Curtain
On Time
. When
Room Temperature
is equal to or above
Target
Tempe Differential
, it will open according to
Curtain On Time
.
This parameter is adjusted in 0.1° increments from 0.4°F to 19.9°F (0.2°C to
13.9°C).
Low Temperature alarm set point
Set 2
This parameter sets the temperature below which a low temperature alarm
condition will occur. When the temperature sensor’s reading decreases to
Low Temperature alarm set point
or below, the alarm relay and LED will
be activated and the
Curtain Idle Time
will be overridden. This parameter
is adjusted in 0.1° increments from OFF, 0.1°F to 99.8°F (-17.7°C to
37.7°C).
High Temperature alarm set point
Set 3
This parameter sets the temperature above which a high temperature alarm
condition will occur. When the temperature sensor’s reading increases to
High Temperature alarm set point
or above, the alarm relay and LED will
be activated and the
Curtain Idle Time
will be overridden. This parameter
is adjusted in 0.1° increments from 0.0°F to 99.8°F, OFF (-17.8°C to
37.7°C).
PC ID
Set 4
This parameter is used to select the identification number that will be used
when communicating with the remote access software. This parameter may
be adjusted to any value from 1 to 250.
Configuration Version
Set 5
This parameter displays the version of the configuration actually used.
Processor Version
Set 6
This parameter displays the version of the processor actually used.
Содержание JD-N2
Страница 3: ...JD N2 WIRING DIAGRAM JD N2 Section A 3 WIRING DIAGRAM JD N2 SECTION A ...
Страница 6: ...JD N2 INSTALLATION JD N2 Section B 6 INSTALLATION JD N2 SECTION B ...
Страница 19: ...JD N2 USER S GUIDE JD N2 Section C 19 USER S GUIDE JD N2 SECTION C ...
Страница 20: ...JD N2 USER S GUIDE JD N2 Section C 20 Control Description 7 3 3 5 1 2 3 4 6 ...
Страница 28: ...JD N2 INDEX WARRANTY JD N2 Section D 28 INDEX WARRANTY JD N2 SECTION D ...
Страница 32: ...JD N2 VER 1 0 February 18th 2010 ...