Barcode Scanning
XT2
User Manual
Janam Technologies LLC Version 3, April 2017
Barcode Scanning 9—2
Scan Settings
Go to
Tools
>
Scan Set-
tings
to configure the XT2’s
scan engine and software.
This is where you set how
the scanner will work, how
it will announce and commu-
nicate results, what all the
scan operation settings
should be and, most impor-
tantly, which of the numer-
ous code symbologies the
scanner should read.
Tab Section Option
Description
Basic
Scanning
Trigger timeout (sec)
Specifies the trigger time out in seconds. If a
barcode is not decoded within the specified
timeout, the default Notifier indicates that
decoding is failed.
Enable Auto Scan
Enable Auto Scan with specified interval.
Auto Scan interval
Set Auto Scan interval time.
Enable Cont. Scan
Enable Continuous Scan without any interval.
Wedge mode
Result Type
Select Result Type :
Keyboard Event
Clipboard(default)
Terminator
Select the desired barcode end method from the
pull down list.
Values: None, Tab, Space, LF
Notification
Beep
Enable Beep
Set enable/disable plays audio sound.
Good read
Set sound to indicate good read.
Bad read
Set sound to indicate bad read.
LED
Enable LED
Set enable/disable visual scan indicators.
Vibrator
Enable Vibrator
Set enable/disable vibrator operation.
Good read
Set vibration time after good read.
Bad read
Set vibration time after bad read.
Wedge
Barcode ID
Transmit Barcode ID
Enable to transmit predefined barcode ID in
Detail tab
Label
Prefix
Enter Prefix to be sent prior to the
decoded/received data.
Suffix
Enter Suffix to be sent after the
decoded/received data
Symbologies
Select barcode types you want to read
There is “Enable All” and “Disable All” to enable/disable all symbologies
About
Specifies Barcode engine type, Firmware revision, Decider revision, API revision
Factory Default
Load Factory Default
After modifying the current settings, if you wish
to return to the factory defaults, tap the Load
Factory Default button.