38
̶
SW-4000M-PMCL
Settings List
Control Tool
: Settings that can only be configured when image capture on the camera is stopped.
Item
Setting range
Default value
Description
a) Device Control
GenCP Version
—
—
Display/configure information related to
the device.
Device Vendor Name
—
“JAI Ltd., Japan”
Display the manufacturer name.
Device Model Name
—
SW-4000M-
PMCL
Display the model name.
Device Manufacturer Info
—
“See the possicilities”
Display the manufacturer information.
Device Version
—
—
Display the device version.
Device ID
—
—
Display the device ID.
Device User ID
Any
—
Set the user ID for the camera.
Device Scan Type
Linescan
Linescan
Display the scan type of the camera.
Device Temperature Selector
Sensor
Sensor, Sensor
Board Bottom,
Interface Board
Bottom, FPGA
Display the location of the temperature
sensor inside the camera.
Device Temperature (Celsius)
—
—
Display the internal temperature (°C) of
the camera.
Device Clock Selector
Camera Link
Camera Link
Select the camera clock.
Device Clock Frequency
84.82MHz,
63.39MHz,
42.41MHz,
31.70MHz
42.41MHz
Select the clock frequency for the
camera.
Device Serial Port BaudRate
Baud 9600,
Baud 19200,
Baud 38400,
Baud 57600,
Baud 115200
Baud 9600
Select the baud rate for the camera's
serial board.
Device Reset
—
—
Reset the device.
b) Image Format Control
Configure image format settings.
Pixel Format
Mono8
Mono10
Mono8
Set the pixel format.
Test Pattern
Off,
Monochrome,
GrayPattern,
White
Off
Select the test image.
Binning Vertical
1, 2
1
Set the number of pixels in the vertical
direction for which to perform binning.
c) Acquisition Control
Configure image acquisition settings.
Trigger Selector
Line Start
Line Start
Select the trigger operation.
Trigger Mode
Off, On
Off
Select the trigger mode.
Trigger Source
CC1(Camera Link),
Hirose 12Pin(TTL)
—
Select the trigger signal source.
Trigger Activation
Rising Edge,
Falling Edge
Falling Edge
(Falling edge of
input signal)
Select the polarity of the trigger signal
(i.e., location of signal at which trigger is
applied).
Trigger OverLap
Off, ReadOut
Off
Select the trigger overlap operation.
Acquisition Line Rate
66 to 10058
*1
10000
Set the line rate as a frequency. (unit: Hz)
Exposure Mode
Off, Timed,
Trigger Width
Timed (control
via exposure
time)
Select the exposure mode.
Exposure Time
3 to 97
*1
97
Set the exposure time.
The maximum value when [Trigger Mode]
is set to [Off] varies depending on the
[Acquisition Line Rate Raw] value.
d) Analog Control
Configure analog control settings.
*
1