̶
16
̶
SW-4000M-PMCL
2
Set [Exposure Mode] to [Trigger Width] .
3
If necessary, change the [Trigger Source] and [Trigger Activation] settings.
Control Without External Triggers
When Controlling the Exposure Time Using Specified Exposure Times
Configure the settings as follows.
Item
Setting value / selectable range
Trigger Selector (trigger operation)
Line Start
Trigger Mode
Off
Exposure Mode
Timed (control via exposure time)
Exposure Time
Varies depending on the Tap Geometry and CL Pixel Clock
settings.
1
Set [Exposure Mode] to [Timed].
([Timed] is the default setting.)
2
Set [Trigger Mode] to [On].
3
Specify a line period slower than the exposure time in [Acquisition Line rate].
4
Specify the exposure time in [Exposure Time].
When Not Controlling the Exposure Time
Configure the settings as follows.
Item
Setting value / selectable range
Exposure Mode
Off
The exposure will be performed with an exposure time equal to Line Period minus 3.6 µs.
Step 5: Adjusting the Image Quality
To maximize the performance of the camera, configure its basic function in the following order.
* For details on this setting, “Variable Line Rate” (page 34) and “Electronic Shutter” (page 35). The exposure
times and line rates that can be set will vary depending on the CL clock and Tap Geometry settings for Camera
Link.
1
Configure the gain.
❖
For details on this setting, see “Gain Control” (page 32).