22
̶
SW-4000M-PMCL
Shortest Repetition Period for Triggers
Trigger Mode ON, full resolution
Shortest period (µs)
Exposure Mode OFF
Camera Link
Varies depending on the Tap
Geometry and CL Clock
settings.
12-pin
Exposure Mode Timed
Camera Link
12-pin
PWC
Camera Link
12-pin
Shortest Trigger Pulse Width
Trigger Mode ON
Camera Link
12-pin
Exposure Mode OFF
3 µs
50 µs
Exposure Mode Timed
3 µs
50 µs
PWC
3 µs
50 µs
Image Output Timing
■
Trigger Control
The camera allows Line Start trigger controls to be performed via external trigger signals.
The Line Start trigger allows exposure control via the trigger signal inputs.
The settings for exposure control and triggers are related to each other. Be sure to configure the settings
described in “Connecting to the Camera to Control Tool” (page 14).