SP-5000M-USB / SP-5000C-USB
- 27 -
6.4 Output timing
6.4.1 Horizontal timing
The horizontal timing of the SP-5000-USB is described below. Although the SP-5000-USB has a
horizontal binning function, its horizontal frequency does not change if it is ON. So, the frame
rate is not increased.
FVAL Active
(a) LVAL Active
(b)
(c) H-Offset
Internal FVAL
Internal LVAL
Internal DVAL
Internal DATA
DVAL Active
Fig.17 Horizontal Timing (Vertical timing OFF)
Table - 17 Timing parameters in Continuous Trigger mode
Camera Settings
(a)
(b)
(c)
T
a
p
G
e
o
m
e
tr
y
P
ix
e
l
C
lo
c
k
ROI
Binning
LVAL
Active
LVAL
Non-Active
H-Offset
Width
Offset
X
Heigh
t
Offset
Y
Horizo
ntal
Vertic
al
[Unit:
Clock]
[Unit:
Clock]
[Unit:
Clock]
8-Bit
48
MHz
2560
0
2048
0
1
(Off)
1
(Off)
320
14
0
1280
0
2048
0
2
(On)
1
(Off)
160
174
0
2560
0
1024
0
1
(Off)
2
(On)
320
14
0
1280
0
1024
0
2
(On)
2
(On)
160
174
0
10-Bit
48
MHz
2560
0
2048
0
1
(Off)
1
(Off)
320
82
0
1280
0
2048
0
2
(On)
1
(Off)
160
242
0
2560
0
1024
0
1
(Off)
2
(On)
320
82
0
1280
0
1024
0
2
(On)
2
(On)
160
242
0
12Bit
48
MHz
2560
0
2048
0
1
(Off)
1
(Off)
320
166
0
1280
0
2048
0
2
(On)
1
(Off)
160
326
0
2560
0
1024
0
1
(Off)
2
(On)
320
166
0
1280
0
1024
0
2
(On)
2
(On)
160
326
0