SP-5000M-USB / SP-5000C-USB
- 37 -
Table23 Trigger control
7.3.1 Trigger Selector
Selects the trigger operation. In the SP-5000-USB, the following trigger operation can be
selected as the trigger.
Table24. Trigger selector
7.3.2 Trigger Mode
Select either free-running operation or external trigger operation.
OFF:
Free-running operation
ON:
External trigger operation
7.3.3 Trigger Source
The following signals can be used as the trigger source signal.
In the following table, Line 10 and Line 11 are effective if optional AUX type 3 is used.
Camera Settings
JAI Custom
Trigger Mode
Name
Description
Trigger
Selector
Trigger
Option
Trigger
Mode
Exposure
Mode
Frame
Start
Off
Off
Off
Continuous
Trigger
Free running operation with the
maximum exposure time per the frame
rate
Off
Timed
Off
Continuous
Trigger
Free running operation with a user-set
exposure time.
On
Timed
Off
EPS Trigger
Externally triggered operation with a
user-set exposure time
On
Timed
RCT
RCT Trigger
Externally triggered operation for RCT
On
Timed
PIV
PIV Trigger
Externally triggered operation for PIV
On
Trigger
Width
Off
PWC Trigger
Externally triggered operation with a
pulse width exposure time
Trigger Selector Item
Description
Acquisition Start
Set to start Acquisition or not
Acquisition End
Set to end Acquisition or not
Frame Start
Set to start Frame control or not
Acquisition Transfer Start
Set to start the stream or not