SP-5000M-USB / SP-5000C-USB
- 32 -
7.1.1.3 Continuous
In this mode, when the AcquisitionStart command is set, the image is continuously output at the
current frame rate. This is the default setting for the SP-5000M-USB and SP-5000C-USB.
1) AcquisitionStart command is input
2) AcquisitionTriggerWait becomes effective
3) AcquisitionActive becomes
“
TRUE”
4) Images begin outputting continuously
5) AcquisitionStop command is sent
6) AcquisitionActive becomes
“
FALSE”. At this moment, the output stops.
However, if AcqusitionStop command is initiated during image output period,
AcqusitionActive becomes “FALSE” (stop capturing) after image output is completed.
Acquisition Start
Acquisition
Trigger
Wait
Acquisition
Active
Acquisition
Trigger Wait
Exposure Active
Frame Active
CCD Readout
Stream Active
Acquisition Status
Frame 1
Frame N
Acquisition Stop
Note: This drawing shows if the trigger is OFF. If the trigger is ON, FrameActive turns to
True at a different AcquisitionActive timing.
Associated commands
:
Acqusition Start, Acqusition Stop
7.1.2 AcquisitionStart
This is the command to start Acquisition.
7.1.3 AcquisitionStop
This is the command to stop Acquisition.