SP-5000M-USB / SP-5000C-USB
- 41 -
7.6. Trigger width mode
In this mode, the exposure time is equal to the trigger pulse width. Accordingly, longer
exposure times are supported. Additional settings determine if the trigger pulse can be accepted
during the exposure period.
Primary settings to use this mode
Exposure Mode:
Trigger Width
Trigger Mode: ON
Trigger Option: OFF
Table - 29 Minimum Trigger Interval ( at 8-bit)
Read out
mode
FULL
2/3 ROI
1/2 ROI
1/4 ROI
1/8 ROI
1/2V Binning
Minimum
Interval (ms)
16.14ms
+8.01µs
13.44ms
+8.01µs
8.07ms
+8.01µs
4.04ms
+8.01µs
2.02ms
+8.01µs
8.07ms+8.01µs
(Note1)
Note1: Only SP-50000M-USB
Note2: The above applies if the trigger Overlap is set to READOUT. If it is set to OFF, the
value is longer than this table.
7.6.1 If the overlap setting is “OFF”
Trigger
CMOS
Exposure
FVAL
Exposure
Active
Exposure Period
t3
t1
t2
Fig.36 Overlap = OFF
t1
t2
t3
2L (Min)
208 clk
7L
~
8L