SP-12401M-USB/SP-12401C-USB
— 62 —
PulseGeneratorEndPointMs
(ms)
1/ PulseGeneratorClock (MHz)
〜
1048575 /
PulseGeneratorClock (MHz)
Set the start point of the Low interval in
milliseconds.
When the counter reaches this value, the
output will be 0.
The setting range varies depending on the
[ClockPreScaler] value.
PulseGeneratorPulseWidth
(ms)
ー
33.3333
Display the High interval width of the pulse
in milliseconds.
The duration between the Start Point and
End Point is calculated. The setting range
varies depending on the [ClockPreScaler]
value.
PulseGeneratorRepeatCount
0 〜 255
0
Set the repeat count for the counter. When
this is set to [0], a free counter is enabled
with no repeat limit.
PulseGeneratorClearActivation
Off,
LevelHigh,
LevelLow,
RisingEdge,
FallingEdge
Off
Set the clear signal condition for the count
clear input of the pulse generator.
PulseGeneratorClearSource
Low
High
AcquisitiionTriggerWait
AcquisitionActive
FrameTriggerWait
FrameActive
ExposureActive
FVAL
LVAL
PulseGenerator0
PulseGenerator1
PulseGenerator2
PulseGenerator3
UserOutput0
UserOutput1
UserOutput2
UserOutput3
Line5 - OptIn1
Line6 - OptIn2
NAND0Out
NAND1Out
Action1
Action2
Low
Select the count clear input signal source.
PulseGeneratorClearInverter
True, False
False
Select whether to invert the polarity of the
count clear input signal.
PulseGeneratorClearSyncMode AsyncMode, SyncMode AsyncMode
Select the sync mode for the count clear
input signal.