SP-12401M-USB/SP-12401C-USB
— 70 —
Input range
Consumption
33.5LSB@10bit
Blemish
correction
Detection
Detect white blemishes using threshhold values
(100 steps available)
(black blemish correction performed only at factory)
Correction
Interpolation using adjacent pixels
(continuous blemishes not corrected)
Correctable pixels
800 pixels
White
balance
Default level
Video level adjustment range
Resolution adjustment
Black Level
adjustment
Manual adjustment range
AnalogAll : 0dB 〜 24dB
DigitalRed : -7dB 〜 15dB
DigitalBlue : -7dB 〜 15dB
Gain
adjustment
Auto gain
Off, Continuous, Once
Off, Continuous, Once,
Preset3200K, Preset5000K, Preset6500K, Preset7500K
16 (4 x 4) Area
3000K 〜 9000K
WBA
BalanceWhiteAuto
Area
Adjustment range
DigitalRed, DigitalBlue : -7dB 〜 15dB
SP-12401M-USB
DigitalAll : 0 ~ 97 LSB@10bit
SP-12401C-USB
(PixelFormat : BGR8, BGR10p)
DigitalAll : 0 ~ 97 LSB@10bit
DigitalRed : 17.5 ~ 49.5 LSB @10bit
DigitalBlue : 17.5 ~ 49.5 LSB @10bit
(PixelFormat : BayerRG8, BayerRG10, BayerRG10p)
DigitalAll : 0 ~ 97 LSB@10bit
DigitalRed : 26 ~ 41 LSB @10bit
DigitalBlue : 26 ~ 41 LSB @10bit
0.25LSB@10bit
Vibration resistance
10G(20 Hz 〜 200 Hz X-Y-Z direction)
Impact resistance
80G
ALC
Can be adjusted automatically together with AGC and auto
Gamma
0.45, 0.5, 0.55, 0.6, 0.65, 0.75, 0.8, 0.9, 1.0
(9 steps available)
Dimensions (housing)
44 × 44 × 44 mm(WHD)(excluding mount protrusions)
DC + 12 V 〜+ 24 V ± 10%(Via input terminal)
3.7. W(typ.)
(at 12 V input, default setting, 25 ℃ environment)
5.0. W(max.)
Power
supply
12-pin
Connector
LUT
OFF:γ= 1.0, ON = 257 points can be set
Weight
130 g
Verified performance temperature / humidity
5℃〜+ 45℃ / 20%〜 80%(non-condensing)
Storage temperature / humidity
25℃〜+ 60℃ / 20%〜 80%(non-condensing)
Regulations
CE(EN61000-6-2 and EN61000-6-3), FCC part 15 class B,
RoHS, WEEE
Lens mount
C-mount
Lens mount protrusion length of 9 mm or less is supported
Flange back
17.526, tolerance: 0 mm to -0.05 m
Optical filter
IR cut filter (SP-12401C-PGE only)
Package contentsCamera
body (1)
Sensor protection cap (1)
Dear Customer (sheet) (1)
Optional accessories (not supplied)
MP-45 tripod mount
Design and specifications are subject to change without notice.
Approximately 30 minutes of warm-up are required to achieve these specifications.
About the verified performance temperatureMake sure the following temperature conditions are
met when operating the unit.
1) The camera's internal temperature sensor detects temperatures of 72°C or less during
operation.
2) The top surface of the camera's casing is 57°C or less.
If the above temperature conditions are exceeded, take measures to dissipate heat according to
your installation environment and conditions.
Caution
Содержание SP-12401M-USB
Страница 72: ...SP 12401M USB SP 12401C USB 72 SP 12401C USB Sensitivity Wave length nm Sensitivity ...
Страница 73: ...SP 12401M USB SP 12401C USB 73 Dimensions Dimenstional tolerance 0 3mm Unit mm ...
Страница 77: ...SP 12401M USB SP 12401C USB 77 Revision Date Changes Revision history 1 1 Jan 2021 China RoHS ...