Setting range
Default value
Description
Configure counter settings. (This camera
only supports counter functions.)
Counter0
Counter1
Counter2
Counter3
ー
Select the counter.
CounterEventSource
Counter0
Off, FrameTrigger
Counter1
Off, ExposureStart
Counter2
Off, SensorReadOut
Counter3
Off, FrameTransferEnd
Off
Assign the counter event signal for which
you want to read the count value to a
dedicated counter, and read the value.
CounterEventActivation
ー
ー
Set the count timing.
The setting value is fixed with the following
data.
Counter0 RisingEdge
Counter1 RisingEdge
Counter2 RisingEdge
Counter3 FallingEdge
CounterReset
ー
ー
Reset the counter.
CounterRefresh
0〜65535
0
Update the count value.
CounterValue
0〜65535
0
Display the count value.
CounterStatus
ー
ー
Display the counter status.
CounterIdle: Idle
CounterActive: Counting
CounterOverflow: Count value exceeded the
mazimum value
Setting range
Default value
Description
Configure user settings.
Default,
UserSet1,
UserSet2,
UserSet3
Default
Select the user settings.
UserSetLoad
0(default), 1, 2, 3
ー
Load user settings.
(If 0 is specified, the factory default setting is read.)
UserSetSave
1,2,3
ー
Save the current setting values as user
settings.
Item
Item
UserSetSelector
CounterSelector
h)CounterAndTimerControl
i)UserSetControl