SP-12401M-USB/SP-12401C-USB
— 61 —
Setting range
Default value
Description
0〜10000
0
PendingAck function test command.
The camera waits for TestPendingAck (ms)
time and returns an Ack response.
Setting range
Default value
Description
Display information on transport layer
control.
Display the payload size.
Geometry_1X_1Y
Geometry_1X_1Y
Set the transfer method (tap configuration)
of images transferred from the camera at
one time.
Setting range
Default value
Description
Configure pulse generator settings.
1〜4096
165
Set the division value for the prescaler (12
bit) using PixelClock as the base clock.
0.0181274〜74.25
0.45
Set the clock used for the pulse generator.
This value is calculated using the
[ClockPreScaler] value as a base.
PulseGenerator0,
PulseGenerator1,
PulseGenerator2,
PulseGenerator3
PulseGenerator0
Select the pulse generator.
PulseGeneratorLength
1〜1048575
30000
Set the maximum count-up value as a clock
count.
PulseGeneratorLengthMs (ms)
1 / PulseGeneratorClock (MHz)
〜1048575 /
PulseGeneratorClock (MHz)
66.6667
Set the maximum count-up value in
milliseconds.
This value is calculated using the
[PulseGeneratorLength] value as a base.
The setting range varies depending on the
[ClockPreScaler] value.
PulseGeneratorFrequency (Hz)
PulseGeneratorClock (MHz) ÷
1048575 x 1000000 〜
PulseGeneratorClock (MHz) x
1000000
Set the maximum count-up value as a
frequency.
This value is calculated using the
[PulseGeneratorLength] value as a base.
PulseGeneratorStartPoint
0 〜 1048574
0
Set the start point of the High interval as a
clock count. When the counter reaches this
value, the output will be 1.
PulseGeneratorStartPointMs
(ms)
0 〜 1048575 /
PulseGeneratorClock (MHz)
0
Set the start point of the High interval in
milliseconds.
When the counter reaches this value, the
output will be 1.
The setting range varies depending on the
[ClockPreScaler] value.
PulseGeneratorEndPoint
1 〜 1048575
15000
Set the start point of the Low interval as a
clock count. When the counter reaches this
value, the output will be 0.
Item
Item
Item
DeviceTapGeometry
PlayloadSize (B)
TestPendingAck (ms)
PulseGeneratorSelector
PulseGeneratorClock (MHz)
ClockPreScaler
n)PulseGenerator
l)TestControl
m)TransportLayerControl