Page 22
TS-2030EN/TS-2076EN Series Progressive Scan Cameras
Tutorial
3.6 Maintenance
3.6.1 Debug Counters
For debugging purposes, some status registers are available as debug counters.
Detailed information for each debugging counter is included in the LC-EN Interface document. This
tutorial covers the following debug counters.
•
Trigger Filter Noise count = number of hardware TTL triggers that failed trigger noise filter.
•
PRE Filter Noise count = number of hardware TTL triggers that failed PRE filter.
•
POST Filter Noise count = number of hardware TTL triggers that failed POST filter.
•
Valid Trigger count = number of hardware TTL triggers that passed noise filter, PRE filter, and POST
filter.
•
VINIT count = number of reset signals sent to CCD
•
IRQ count = number of interrupt generated by FPGA to PowerPC
Содержание Pulnix TS-2030EN Series