IIT Camera System Manual
42
Appendix G
5
Connect the camera to
the Ethernet port of an
appropriate test PC.
Switch on the camera
power. Launch EN Setup
application
Sec. 4
6
Align camera
mechanically to correct
position by adjusting
the VIS Mount and using
the tools from EN
Setup.
Do not adjust
the camera mount
inside the housing.
Sec. 4
7
Focus lens and make
sure that the lens iris is
fully open and no
polarizer is mounted.
Secure locking screws
after adjustment
Appendix B
8
Properties settings using
internal Light Sensor:
Sec. 4.1
(IIT IO Board settings: X=05, Y=0A, M=C8, K=01, P=3A, Q=03, T=96)
Properties settings using
external Light Sensor:
Sec 4.2
(IIT IO Board settings: X=05, Y=0A, M=C8, A=10)