Timing chart (GOX-3201MC-PGE)
— 34 —
Go-X Series GigE Vision I/F
Next trigger disabled
Next trigger
Input enabled
B
Exposure time
Trigger
Sensor
Exposure
Exposure
Active
Readout
■
When [ExposureMode] is [Timed]
• FrameStartTrigger On
A (Frame Period)
PixelFormat
Frame Period [A] (usec)
Period From Trigger start edge to
Exposure start [B] (usec)
Mono8
27397
35.2
Mono10/Mono12
54945
66.5
Mono10Packed/Mono12Packed
41153
66.6
Bayer8
27397
35.2
Bayer10/Bayer12
54945
66.5
Bayer10Packed/Bayer12Packed
41153
66.6
Horizontal Binning On
Mono8
17921
35.3
Mono10
34365
66.6
Mono10Packed
34365
66.6
Mono8
17921
35.2
Mono10
34365
66.6
Mono10Packed
34365
66.6
Mono8
17921
35.3
Mono10
34365
66.6
Mono10Packed
34365
66.6
Vertical Binning On
Binning Off