— 24 —
Exposure Mode
ExposureMode = Off
ExposureMode = Timed
ExposureMode = TriggerWidth
Mode in which control is performed using exposure time. Acquire images using an
exposure time configured beforehand on an external trigger.
In this mode, the exposure time can be adjusted automatically by setting
[ExposureAuto]. For details, refer to “ALC (Automatic Brightness Control) Function”.
Mode in which control of the exposure time is performed using the pulse width of
the trigger input signal. The exposure time will be the same as the pulse width of
the trigger input signal.
Exposure control is not performed (free-running operation).
The exposure time is the longest possible time within the operating conditions such
as the frame rate.
Exposure
Trigger
•
The settings for exposure control and triggers are related to each other. Be sure to
configure the settings described in “Trigger Control”.
Actual Exposure Times
This camera has three Exposure modes (Off, Timed, TriggerWidth).
Use [AcquisitionControl] settings to perform operations and settings for exposure.
The actual exposure time will consist of the image sensor’s offset duration
(refer to
the table below) added to the setting configured on the camera.
(Example for GOX-3201M-PGE)
When [ExposureMode] is set to [Timed] and the exposure time is set to 1
μs
, the
actual exposure time will be as follows.
1
μs
+ 13.7
μs
(offset duration of image sensor) = 14.7
μs
When [ExposureMode] is set to [TriggerWidth], the exposure is slightly longer than
the width of the trigger signal. To achieve an exposure time of 14.7
μs
and the
exposure time offset is 13.7
μs
, use 14.7
μs
- 13.7
μs
= 1
μs
as the high or low
time for the trigger signal.
Go-X Series GigE Vision I/F
Model name
Image sensor's offset
GOX-2402M-PGE
GOX-2402C-PGE
GOX-3201M-PGE
GOX-3201C-PGE
GOX-5103M-PGE
GOX-5103C-PGE
GOX-8901M-PGE
GOX-8901C-PGE
GOX-12401M-PGE
GOX-12401C-PGE
14.26μs
13.73μs
The offset time varies depending
on the model as shown in the table
on the left.
Содержание GOX-2402M-PGE
Страница 79: ...Go X Series GigE Vision I F Spectral Response GOX 2402MC PGE 79...
Страница 80: ...80 Spectral Response GOX 3201MC PGE Go X Series GigE Vision I F...
Страница 81: ...81 Spectral Response GOX 5103MC PGE Go X Series GigE Vision I F...
Страница 82: ...Go X Series GigE Vision I F Spectral Response GOX 8901MC PGE 82...
Страница 83: ...Go X Series GigE Vision I F Spectral Response GOX 12401MC PGE 83...
Страница 84: ...84 Dimensions Dimenstional tolerance 0 3mm Unit mm Go X Series GigE Vision I F...
Страница 88: ...88 Revision Date Changes Revision history Go X Series GigE Vision I F...