AT-200CL
- 26 -
8.4.2 Horizontal timing
Fig. 30 Horizontal timing for V binning.
9. Operation Modes
This camera can operate in 5 primary modes.
1.
TR=0 Con
Normal continuous Mode
Pre-selected exposure.
2.
TR=1 EPS
Edge Pre-select Mode
Pre-selected exposure.
3.
TR=2 PWC Pulse Width Control Mode
Pulse width controlled exposure.
4.
TR=3 RCT Reset Continuous Mode
Pre-select exposure
5.
SL Smearless Mode
9.1. Continuous operation
For applications not requiring asynchronous external triggering, this mode should be used. In
this mode it possible to use a lens with video controlled iris.
For timing details, refer to fig.26. through fig. 31
.
To use this mode:
Set function:
Trigger mode to “Continuous”
TR=0
Scanning
SC=0, 1
Vertical binning
VB=0, 1
Shutter mode normal, programmable SM=0 through 3
Shutter speed
SH=0 through 11
Programmable exp.
PE=0 through 1252
Other functions and settings
D V A L
Effective Pixels
F V A L
S U B
S G
E E N
1 L V A L p e r i o d
L V A L
X E E N
(Hirose 12pin)
2 9 c k
2 9 c k
1 6 2 8
1 6 2 8
2 2 1 6
5 2 8
4 8 c k
1 2
O B
D u m m y +
B l a n k
O B
5 2 8
1 6 8 8
FVAL raising edge
Exposure
Period
DATA out
CCD out
FVAL falling edge
ck
ck
330
835 (16.7μs)
185
1020
2138
528
76
120
1688