AT-200CL
- 37 -
LUTB
LUT data communication
(For Blue)
LUTB=[Param.]<CR><L
F>
LUTB?<CR><LF>
transfer by a serial method.
The number of the data is 512.
Param: 0 to 8191
TPN
Test pattern
TPN=[Param.]<CR><LF
>
TPN?<CR><LF>
0=OFF
1 to 15 pattern
RF
RCT FVAL Type
RF=[Param.]<CR><LF>
RF?<CR><LF>
0=Camera Link Standard
1=JAI Standard
CM
Center Marker
CM=[Param.]<CR><LF>
CM?<CR><LF>
Upper
4
bit
Center marker RGB Indicate
Bit6 bit5 bit4
R-Ch G-Ch B-Ch
1:on 1:on 1:on
0:off 0:off 0:off
Lower 4bit
0=Normal Mode, 1=Vertical Bar
2=Horizontal Bar ,3=Both
CMTX
Color Matrix
CMTX=[Param.]<CR><L
F>
CMTX?<CR><LF>
0=Linear 1=sRGB
2=Adobe RGB 3=User
MGRR
3
R_R_MATRIX_GAIN
MGRR3=,[Param.]<CR>
<LF>
MGRR3?<CR><LF>
-2048 to 2047
MGRG
3
R_G_MATRIX_GAIN
MGRG3=[Param.]<CR>
<LF>
MGRG3?<CR><LF>
-2048 to 2047
MGRB
3
R_B_MATRIX_GAIN
MGRB3=[Param.]<CR>
<LF>
MGRB3?<CR><LF>
-2048 to 2047
MGGR
3
G_R_MATRIX_GAIN
MGGR3=[Param.]<CR>
<LF>
MGGR3?<CR><LF>
-2048 to 2047
MGGG
3
G_G_MATRIX_GAIN
MGGG3=[Param.]<CR>
<LF>
MGGG3?<CR><LF>
-2048 to 2047
MGGB
3
G_B_MATRIX_GAIN
MGGB3=[Param.]<CR>
<LF>
MGGB3?<CR><LF>
-2048 to 2047
MGBR
3
B_R_MATRIX_GAIN
MGBR3=[Param.]<CR>
<LF>
MGBR3?<CR><LF>
-2048 to 2047
MGBG
3
B_G_MATRIX_GAIN
MGBG3=[Param.]<CR>
<LF>
MGBG3?<CR><LF>
-2048 to 2047
MGBB
3
B_B_MATRIX_GAIN
MGBB3=[Param.]<CR>
<LF>
MGBB3?<CR><LF>
-2048 to 2047
NRC
Noise reduction
NRC=[Param.]<CR><LF
>
NRC?<CR><LF>
0=FF 1=ON
NRS
Noise reduction threshold
NRS=[Param.]<CR><LF
>
NRS?<CR><LF>
0 to 255
0=FF, 255=max
TMS
Temperature sensor
TMS?<CR><LF>
-880 to 2400
/16 -=
℃
(-55 to 150
℃
)
G
–
Saving and loading data in EEPROM
LD
Load settings from
camera EEPROM
LD=
Param.
<CR><LF>
0=Factory data
2=User 2 area
1=User 1 area
3=User 3 area
Latest used data
defa. at power up
SA
Save settings to
camera EEPROM
SA=
Param.
<CR><LF>
2=User 2 area
1=User 1 area
3=User 3 area
Parameter = 0 is
not allowed
EA
EEPROM area request
EA?<CR><LF>
0=Factory data
2=User 2 area
1=User 1 area
3=User 3 area
Return latest used
area
!!
Do not try to use commands not shown in this list.