AP-1600T-PMCL | AP-3200T-PMCL | User Manual (Ver. 2.0)
Setting List (Feature Properties)
- 95 -
ALC Control Item
Setting Range
Default
Description
AutoGainControlGainRaw
Min
100 ~ (AutoGainControlGain
RawMax - 1)
100
Set the minimum value for the GainAuto(ASC) control
range.
AutoGainControlGainRaw
Max
(AutoGainControlGain
1) ~ 800
400 or 800
Set the maximum value for the GainAuto(ASC) control
range. The default value depends on the Gain setting.
ALCControlMode
Standard
Ratio
Standard
Specify the ALC control speed.
Standard: Control the speed in ALCControlSpeed. Set from
1 ~ 8 (fastest).
Ratio: Control the speed in ALCControlRatio. Set from 1 ~
100 %(fastest).
ALCControlSpeed
1 (slow) ~ 8 (fast)
4
Set the response speed for AGC/ ASC. (8 is the fastest.)
(When ALCControlMode is set to Standard.)
ALCControlRatio
1 ~ 100 (%)
90
Set the response speed for AGC/ ASC. (100 is the fastest.)
(When ALCControlMode is set to Ratio.)
ALCStatus
Off
ASC
AGC
-
Allows confirmation of the current operation area during
ALC operation.
AutoControlStatus
Executing ASC
Executing AGC
Executing ASC and AGC
Executing AWB
Executing ASC and AWB
Executing AGC and AWB
Executing ASC and AGC and
AWB
Convergen
Idle
-
Allows confirmation of the AGC, ASC, and AWB
convergence status.