AP-1600T-PMCL | AP-3200T-PMCL | User Manual (Ver. 2.0)
Short ASCII Command List
- 104 -
Name
Access
Short
ASCII
Values
MIN
MAX Default
Description
DeviceSerialPort
BaudRate
R/W
CBDRT
READ: Indicate current baud
rate WRITE: Set any bit of baud
rate
1(0x01):Baud9600
2(0x02):Baud19200
4(0x04):Baud38400
8(0x08):Baud57600
16(0x10):Baud115200
A single bit may be set
according to the current
baudrate setting.0 is an invalid
value.
1
(0x01)
16
(0x80)
1 (0x01)
CBDRT=[Param.]<CR><LF>
CBDRT?<CR><LF>
In case of WRITE execution (change
baud rate), it needs to control in the
proper sequence between Host and
Camera.
Display the currently configured
transmission baud rate. To change
the transmission baud rate, use this
command.
Device Control (Command List)
Note:
For more information on each setting, see
(Setting List).
Name
Interface
Access
Short
ASCII
Values
Default
Description
DeviceFirmware
Version
R/O
VN
-
-
VN?<CR><LF>
DeviceFpgaVersion
R/O
FPVN
-
-
FPVN?<CR><LF>
Version of the FPGA in the device.
DeviceManifestXML
Version
R/O
XMLVR
-
-
XMLVR?<CR><LF>
Indicates the version number of the GenICam XML file.
DeviceTemperature
R/O
TMP0
-7040 ~
16000
0
TMP0?<CR><LF>
Value/128 = Device Temperature in degrees Celsius (C)
DeviceReset
W/O
CRS00
1
-
CRS00=1<CR><LF>
Resets the device to its power up state. After reset, the device
must be rediscovered.