AP-1600T-PMCL | AP-3200T-PMCL | User Manual (Ver. 2.0)
Short ASCII Command List
- 103 -
GenCP Bootstrap Register
Note:
For more information on each setting, see
(Setting List).
Name
Access
Short
ASCII
Values
Default
Description
DeviceVendorName
R/O
DVN
"JAI Corporation"
-
DVN?<CR><LF>
DeviceModelName
R/O
MD
AP-1600T-PMCL
AP-3200T-PMCL
-
MD?<CR><LF>
DeviceVersion
R/O
DV
Indicate device version (e.g. “0.1.0.0” )
-
DV?<CR><LF>
DeviceSerial
Number
R/O
ID
Serial Number
-
ID?<CR><LF>
DeviceUserID
R/W
UD
User can save and load free text. (64 or less
characters)
-
UD=[Param.]<CR><LF >
UD?<CR><LF>
Technology Specific Bootstrap Register
Name
Access
Short
ASCII
Values
MIN
MAX Default
Description
DeviceSerialPort
SupportedBaudRate
R/O
SBDRT
READ: Indicate supported
Baudrate.
1(0x01):BaudRateMax_9600
3(0x03):BaudRateMax_19200
7(0x07):BaudRateMax_38400
15(0x0F):BaudRateMax_
57600
31(0x1F):BaudRateMax_
115200
63(0x3F):BaudRateMax_
230400
127(0x7F):BaudRateMax_
460800
255(0xFF):BaudRateMax_
921600
Multiple bits may be set
according
1
(0x01)
255
(0xFF)
31
(0x1F)
SBDRT?<CR><LF>
Display the supported transmission
baud rate as bit fields
This camera supports 9600bps,
19200bps, 38400bps,57600bps, and
115200bps.