Installation
Item no. 10501004, Revision 03
25 ( 40 )
8.4
Setting concentricity
The concentricity of the HF spindle is already set ex-works.
1
High Frequency Spindle
2
Inner taper of shaft
3
Radial adjustment screws (4 x ISO 4026-M5x8)
4
Axial clamping screws (6 x ISO 4017-M5x16)
5
taper adapter
6
Meter
If the concentricity needs to be reset, proceed as follows:
Ü
Completely disconnect the power supply.
Ü
Completely disconnect the media supply (air and liquid).
Ü
Make sure that the shaft of the HF spindle has come to an absolute stand-
still.
Ü
Set the main spindle of the machine tool to no-load operation.
Ü
Remove all connections from the HF spindle.
Ü
Unscrew the clamping nut and collet.
Ä
See section: manual tool change
Ü
Clean the inner taper of the shaft.
Ü
Position the button of the meter at the inner taper of the shaft.
Ä
Precision 0.001 mm