J-200
all north american J-210 Convertible Models (60 hz)
120V/15A†
240V/30A†
240V/40A
‡
Circuit Breaker:
15A†, 1-Pole 30A†, 2-Pole 40A
‡
, 2-Pole
Number of Wires:
3 (15A GFCI
Cord US
Only*)
4 (Hard Wire
Only)
4 (Hard Wire
Only)
Frequency:
60 Hz
60 Hz
60 Hz
Current Draw:
12A
21A
30A
* all Canadian spas must be hard wired per Csa Canadian standards
(page 8).
†
In 15A/30A configuration, the heater
will not operate
while the jets
pump is running in high speed.
The factory setting is 120V/15A.
‡
In 40A configuration, remove jumper JP1-2 on the board, to allow the
heater to
operate
when the jets pump is running in high speed.
CauTIon (For 4-wire 240 vaC Heater operation): move the red
wire on the main terminal strip (TB1) from position #1 to position
#3. make certain wires are connected exactly as shown in Figure
D (page 18)
before applying power
. Failure to do so will result in
damage to the circuit board and/or related components and void
the manufacturer’s warranty.
export J-270 and J-280 models (50 Hz)
230V/20A*
230V/30A**
230V/40A***
Circuit Breaker:
20A
*
30A
**
40A
***
Number of Wires:
3
3
3
Frequency:
50 Hz
50 Hz
50 Hz
Current Draw:
15A
23A
29A
*
In 20A configuration, the heater
will not operate
while either jets
pump is running in high speed.
This is the factory setting. Note:
pump 2 runs only in high speed.
**
In 30A configuration, the heater will
operate
while one jets pump is
running in high speed.
Note: pump 2 runs only in high speed.
***
In 40A configuration the heater
will operate
while both jets pumps
are running in high speed.
14