J-200
6.0 power requirements
Jacuzzi spas are designed to provide optimum performance and
flexibility of use when connected to the maximum electrical service listed
below. Minor circuit board modifications can be performed to allow your
new spa to accept an electrical service other than the factory operation
setting.
note:
Refer to pages 44-47 for circuit board configuration details or
contact your authorized Jacuzzi dealer.
all north american J-270 and J-280 models (60 Hz)
240V/40A*
240V/50A**
240V/60A***
Circuit Breaker (2-Pole):
40A
*
50A
**
60A
***
Number of Wires:
3
3
3
Frequency:
60 Hz
60 Hz
60 Hz
Current Draw:
26A
36A
45A
*
In 40A configuration, the heater
will not operate
while either jets
pump is running in high speed.
Note: pump 2 runs only in high
speed.
**
In 50A configuration, the heater
will not operate
while both jets
pumps are running in high speed.
This is the factory setting.
Note: pump 2 runs only in high speed.
***
In 60A configuration the heater
will operate
while both jets pumps
are running in high speed.
all north american J-230 models (60 Hz)
240V/40A*
240V/50A**
Circuit Breaker (2-Pole):
40A
*
50A
**
Number of Wires:
3
3
Frequency:
60 Hz
60 Hz
Current Draw:
26A
36A
*
In 40A configuration, the heater
will not operate
while the jets
pump is running in high speed.
**
In 50A configuration, the heater
will operate
while the jets pump is
running in high speed.
This is the factory setting.