background image

18

NOTE: Some models have a plastic buckle in
place of the velcro. Once the straps are in place,
pull upward on the buckle to tighten the straps.

Ensure plastic spacer is inserted into collar on the
support plate.

Cleaning the D.E. grid cassette:

Содержание Avalanche

Страница 1: ...nt Ideal for above ground or inground pools your filter system with the Ring Lok filter and Ring Lok pump allows you to easily clean the filter grids and the pump strainer basket without any tools Thi...

Страница 2: ...d plug connected units To reduce the risk of electric shock replace damaged cord immediately For cord and plug connected units Risk of electric shock Connect only to a grounding type receptacle protec...

Страница 3: ...with a 3 prong twist lock 115V plug then the appro priate female receptacle should be installed For systems with a standard 3 prong 115V plug we recommend a grounded receptacle be installed with a bui...

Страница 4: ...ced on inter connect pipe before it is threaded into filter Threads on union nut should face away from the filter Step 2 Place filter on base in upright position with interconnect pipe facing the pump...

Страница 5: ...em set up is complete NOTE Some systems come with grommet nuts or equivalent factory installed Step 5 Be certain that the filter cover is pushed completely down and the Ring Lok nut is tightened to th...

Страница 6: ...Typical above ground pool connection 6...

Страница 7: ...l shut off valves are installed be sure that both valves are fully opened Step 2 Mix diatomaceous earth in a bucket of water See Chart for appropriate amounts The D E scoop this is supplied with your...

Страница 8: ...to coat sufficiently IMPORTANT Do not operate filter for extended periods without D E Step 6 The filter is equipped with a pressure gauge to assist in determining when the filter grid cassette should...

Страница 9: ...property damage Step 1 Unplug the pump cord However if the system has not been operating plug pump cord into 3 prong grounded electrical receptacle allow to run for 5 to 8 minutes then unplug pump cor...

Страница 10: ...s then return wiper blades to bottom position of stroke Step 4 Plug pump into 3 prong grounded electrical receptacle Note pressure reading If pressure gauge reading increases 10 p s i within 72 hours...

Страница 11: ...red in your system drain the filter tank before proceeding For in ground pools with the filter system located above the pool water level Your system is full of water If you remove the pump strainer co...

Страница 12: ...er lid and re lubricate with petroleum jelly Also clean all surfaces that come in contact with the o ring to assure a good seal Step 6 Replace the clear cover and strainer Ring Lok HAND TIGHTEN ONLY O...

Страница 13: ...w of water from your pool To remove the water that is still captured in your system drain the filter tank before proceeding For in ground pools with the filter system located above the pool water leve...

Страница 14: ...nue to unscrew the Ring Lok nut Remove and set aside Step 5 Remove the cover by pulling upward on the handles rocking gently if necessary NOTE Be sure not to bend the threaded wiper rod protruding fro...

Страница 15: ...15 Cleaning the D E grid cassette...

Страница 16: ...16 Cleaning the D E grid cassette...

Страница 17: ...17 Cleaning the D E grid cassette...

Страница 18: ...have a plastic buckle in place of the velcro Once the straps are in place pull upward on the buckle to tighten the straps Ensure plastic spacer is inserted into collar on the support plate Cleaning th...

Страница 19: ...20 Clean the threads of the Ring Lok nut and the threads on the filter body with water or a cloth Place the Ring Lok nut on the filter and tighten to the built in stops Be sure that the yellow safety...

Страница 20: ...anitary water to prevent a spread of germ infection and control the growth of algae which can spoil the appearance and enjoyment of your pool or spa See your pool professional for proper chemical main...

Страница 21: ...21...

Страница 22: ...Reassemble of your equipment makes him the best qualified source 22...

Страница 23: ...l conditions of operation This warranty extends only to the original retail purchaser and only during the time in which the original retail purchaser occupies the site where the product was originally...