background image

P a g e

 | 

 

Installation and Operation Manual 

Zodiac Aquapure Ei Series APURE35PLGC 

by Zodiac Pool Systems, Inc 

2620 Commerce Way 

Vista, California, 92081 USA 

In US: (800) 822-7933 • In Canada (888) 647-4004 

www.ZodiacPoolSystems.com

Swimming pool algicide/bactericide 

Chlorine Generating Device 

For Residential Pools 

DOMESTIC 

REGISTRATION NO. 30233 PEST CONTROL PRODUCTS ACT  

Installation and Operation Manual 

READ THE LABEL AND OPERATION MANUAL BEFORE USING 

KEEP OUT OF REACH OF CHILDREN 

 

Use Copper Conductors Only 

 

Disconnect Power before Opening Service Cover 

 

For Outdoor or Indoor Use 

 

Electrical Requirements:  120 VAC 50/60 Hz 3 WIRE, 1.3 AMP 

 

Maximum Output of Hypochlorous Acid is Equivalent to 420 g  

 

   of Free Available Chlorine Per Day 

 

4,000 parts per million of salt 

 

The maximum volume of water that can be treated with  

 

    one unit of  APURE35PLGC is 132,000 litres  

 

    (35,000 gallons) (132.0 m

3

). 

 

For swimming pools, a range of 1-3 ppm of free available  

 

    chlorine must be maintained. 

 

Controls bacteria and algae in swimming pool water. 

BUILDER/INSTALLER: Please leave this manual with the pool owner. 
POOL OWNER: Please save this manual.

 

WARNING 

FOR YOUR SAFETY - For anything other than the routine cleaning and maintenance described in this manual, this product 
must be serviced by a contractor who is licensed and qualified in pool equipment by the jurisdiction in which the product will 
be installed where such local requirements exists. In the event no such  local requirement exists, the installer or maintainer 
must be a professional with sufficient experience in pool equipment installation and maintenance so that all of the instructions 
in this manual can be followed exactly. Before installing this product, read and follow all warning notices and instructions that 
accompany this product. Failure to follow warning notices and instructions may result in property damage, personal injury, or 
death. Improper installation and/or operation will void the warranty. 
Improper installation and/or operation can create unwanted electrical hazard which can cause serious injury, property 
damage, or death.  
Operating AquaPure model APURE35PLGC without water flow through the cell can cause a buildup of flammable gases 
which can result in FIRE OR EXPLOSION. 

KEEP OUT OF REACH OF CHILDREN 

 

2012-2869
2012-09-05 

Содержание Aquapure Ei APURE35PLGC

Страница 1: ...ase leave this manual with the pool owner POOL OWNER Please save this manual WARNING FOR YOUR SAFETY For anything other than the routine cleaning and maintenance described in this manual this product...

Страница 2: ...he label It is an offence under the Pest Control Products Act to use this product in a way that is inconsistent with the directions on the label The user assumes the risk to persons or property that a...

Страница 3: ...AquaLink RS Control System or PDA Optional 16 3 7 1 Verify the Controller Type on the Power Pack is Set Correctly 16 3 7 2 Wiring to the AquaLink RS Control System or PDA 16 3 7 3 Testing the Connect...

Страница 4: ...rts and Exploded Views 32 8 1 Parts List 32 8 2 Exploded Views 33 Figures Figure 1 Example of Installation 8 Figure 2 Carton Contents 9 Figure 3 Installation Requirements 10 Figure 4 Installation Requ...

Страница 5: ...17 Figure 26 Communication Wiring between Power Pack and AquaLink RS Control System or PDA Network 17 Figure 27 Control Panel on the Power Pack 23 Figure 28 Undo Locking Ring 26 Figure 29 Remove the...

Страница 6: ...e risk of injury do not permit children to operate this device Do not use if supply cord is damaged A damaged supply cord should only be replaced by the manufacturer service agent or electrician When...

Страница 7: ...ot water may induce hyperthermia Hyperthermia occurs when the internal temperature of the body reaches a level several degrees above the normal body temperature of 37 C 98 6 F The symptoms of hyperthe...

Страница 8: ...te a spa or hot tub if the suction fittings are broken or missing Never replace a suction fitting with one rated less than the flow rate marked on the equipment assembly CAUTION This device is intende...

Страница 9: ...ral stone especially when used outdoors be sealed to prevent weathering staining and premature degradation Consult with your stone or deck contractor for the proper sealer for the masonry products you...

Страница 10: ...3cm 10 in x 4 5 in x 13 in Electrolytic Cell L x W x H 16 5 cm x 14 cm x 30 5 cm 6 5 in x 5 5 in x 12 in Pod L x W x H 16 5 cm x 14 cm x 15 3 cm 6 5 in x 5 5 in x 6 in Input Voltage 120 V Input Curren...

Страница 11: ...Power Drill 6 mm 15 64 in Hammer Drill Bit only necessary to drill into brick or concrete Pencil or Marking Pen Phillips Head Screwdriver or Phillips Head Drill Bit 3 2 Installation Requirements WARN...

Страница 12: ...w the power pack bracket into position on a wall surface where it will mount securely while ensuring it is no more than 4 6 m 15 ft from the cell see Figure 4 and 5 3 Position the power pack in place...

Страница 13: ...l is 348 L min 92 gpm If flow rate exceeds 348 L min 92 gpm the cell MUST be plumbed on bypass see Figure 22 A control valve must be installed to regulate the flow through the cell It can be installed...

Страница 14: ...ANDY L M to allow communication between the power pack and the AquaLink RS Control System The default controller type setting on the power pack is Jandy L M Follow the instructions below to verify the...

Страница 15: ...llation 3 7 3 Testing the Connection Once the power pack has been wired to the AquaLink RS Control System or PDA follow these steps to test the connection 1 Apply power to the power pack and the AquaL...

Страница 16: ...to the swimming pool water Nitrates can cause extremely high chlorine demands and will deplete chlorine from your swimming pool In some cases nitrates may even lower your chlorine levels to zero Your...

Страница 17: ...r is tested by a pool professional and properly balanced before turning on the chlorinator system New plaster pools have a constant acid demand for six 6 months Test often and maintain a proper pH to...

Страница 18: ...le method to test the salinity of the pool water Once the existing salinity has been established use Table 1 to determine the amount of salt to add to reach the desired level Be conservative when addi...

Страница 19: ...MPORTANT Turn the power pack off by pressing the ON Off button OFF will be displayed on the screen 3 Test the water for salinity level using test strips electronic meter or by your local pool professi...

Страница 20: ...292 lbs 166 kgs 365 lbs 199 kgs 438 lbs 232 kgs 511 lbs 2500 57 kgs 125 lbs 85 kgs 188 lbs 114 kgs 250 lbs 142 kgs 313 lbs 170 kgs 376 lbs 199 kgs 438 lbs 2750 47 kgs 104 lbs 71 kgs 156 lbs 95 kgs 209...

Страница 21: ...zer reading is between 10 50 ppm and will vary dependent on geographic climate Warm sunny climates will require a stabilizer reading at the higher end of the given range Consult your local pool profes...

Страница 22: ...quaLink RS PDA Control System The Zodiac AquaPure Ei Series APURE35PLGC chlorine generating device can be connected to an AquaLink RS or PDA Control System see Section 3 5 and 3 6 For detailed instruc...

Страница 23: ...on 4 3 4 Calcium Hardness Test pool water for calcium hardness level using test kit or by having a water sample tested by a pool professional Adjust as necessary to maintain a calcium hardness of 200...

Страница 24: ...id solution A foaming action will begin which is caused by scale calcium carbonate being dissolved from the plates If rigorous foaming action does not begin the cell does not need to be cleaned STOP T...

Страница 25: ...ing ring in proper alignment making sure the bump aligns with the top thread 9 Screw down the locking ring to the threaded clamp using the locking ring tool NOTE Ensure the locking ring is level when...

Страница 26: ...ity level of 4 000 ppm 4 500 ppm High nitrate level Contact a pool professional Metals present in pool water Contact a pool professional New pool water Not shocked properly upon startup Super chlorina...

Страница 27: ...is sized properly for required flow rate Flow switch connection loose Check that the flow switch is properly connected to the power pack Flow switch failure Replace the flow switch Problem Possible Ca...

Страница 28: ...e Corrective Action Output Fault appears on the screen Power supply Turn the power off to the power pack and consult your local pool care professional Problem Possible Cause Corrective Action Salt lev...

Страница 29: ...orrective Action Eye and or skin irritation Improper water balance Balance the water to recommended levels in Section 4 4 Problem Possible Cause Corrective Action Scale formation on pool equipment NOT...

Страница 30: ...Ei Pod R0511900 8 R Kit Pod Housing APURE Ei Pod R0512000 Power Pack 9 R Kit Power Supply 120 240V Plug In Version R0511100 Miscellaneous 10 R Kit Locking Ring Tool R0512600 11 R Kit Winterizing Kit R...

Страница 31: ...treated with one unit of model Zodiac AquaPure Ei Series APURE35PLGC is 132 000 litres 132 m3 For swimming pools a range of 1 3 ppm of free available chlorine must be maintained Maximum output of hyp...

Страница 32: ...quaPure Ei Series APURE35PLGC REGISTRATION NUMBERS 30233 PEST CONTROL PRODUCTS ACT This cell must be only used on this model of chlorine generating device Read the label Installation and Operating Man...

Страница 33: ...ormation This service and this information do not replace the official hard copy label The PMRA does not provide any guarantee or assurance that the information obtained through this service is accura...

Отзывы: