9
NOTE: Regeneration of the D.E. filter is done to extend the filter cycle before
cleaning of the grid cassette becomes necessary. If a 10 p.s.i. increase is indi-
cated by the filter pressure gauge, follow the filter regeneration steps below.
If filter Ring-Lok is removed or adjusted under pressure, the filter cover
may blow off, causing injury or major property damage.
Step 1
Unplug the pump cord. However, if the system
has not been operating, plug pump cord into
3-prong grounded electrical receptacle, allow
to run for 5 to 8 minutes, then unplug pump
cord.
NOTE: Do not attempt to regenerate filter
while pump is running.
Step 2
Grasp wiper handle on top of filter. D.E. cake
may prevent easy up and down movement of
wiper plates. To dislodge the D.E. cake, pump
the handle up and down until it moves freely.
Several pumps may be necessary to initiate
any movement of the regenerative system.
Filter regeneration: