51
MAINTENANCE
TROUBLE-SHOOTING
CORRECTIONS
PROBABLE CAUSES
Check belt tension and tighten if necessary.
1- Loose belts.
2- Air in the intake system.
3- Pressure regulator.
c - PRESSURE OSCILATION
Check the regulator components and clean or replace if necessary.
Check for damaged hoses, filter packing rings, etc., and repair
if necessary.
PROBABLE CAUSES
SOLUTIONS
When the pumps runs, liquid will pass through the valve even in the
closed position, however flow will be insuficient.
Valve with sealing deficiency or stuck due to impurities.
1-Filter shut off valve closed.
d -INTERMITTENT PRESSURE
2- Pump valve deficiency.
3- Pump head perforated internally.
Replace it.