38
OPERATION AND ADJUSTMENTS
ATTENTION
The numbers shown in the above example are illustrative. The correct calibration
should be done according to instructions of a technician of trust.
SPRAYER CALIBRATION
The safety of people, animals and environment depends on correct spray appications. Therefore,
we list below important operational procedures.
WHEN HANDLING CHEMICALS
- Follow strictly the instructions on the labels.
- Use individual protective clothing.
- Do not eat, drink or smoke.
- Choose a ventilated place.
- Wash with water and soap the parts of the
body touched by chemicals.
WHEN OPERATING SPRAYER
- Check for the proper working conditions of the
sprayer.
- Do not blow by mouth nozzles, valves or tubes.
- Do not spray against the wind.
- Do not spray at sunny times
- Use individual protective clothing
recommended.
- Do not eat, drink or smoke.
REMEMBER!
You are responsible for the success of the application.
F x 600
S x A
V =
600
2
V =
1.0 x 600
0.5 x 4
( L/ha )
V =
CALIBRATING THE SPRAYER
The sprayer can be calibrated through the formula below or through the calibrator bottle as shown
in the next page.
Nozzle flow rate .............................. 1.0 l/min at 150 psi (JA-2 nozzle)
Nozzle spacing ............................... 0.5 m
Working speed ............................... 4.0 km/h
EXAMPLE
( L/ha )
300 L/ha
=
Where:
V
: Spray volume (L/ha)
F
: Nozzle flow rate (L/min)
A
: Nozzle spacing (m)
S
: Tractor speed (km/h)
600 : Conversion unit
F x 600
S x A
( L/ha )
V =
CALCULATING THE SPRAY VOLUME
Содержание CONDOR B-12