SAFETY DOOR INTERLOCK/DOOR OVERRIDE INSTRUCTIONS
44
Safety Door Interlock Box Bottom
05700-001-21-26
Safety Door Interlock Box Cover
05700-001-21-27
Other Safety Door Interlock (SDI)
components (not shown):
Pipe Clamp (found on the side of the machine)
05700-000-35-05
Solenoid, Electrical Interlock Option
04810-100-61-33
Relay
05945-111-47-51
Latch access hole
The following instructions are for Tempstar HH models equipped with the Safety Door Interlock option. These instructions are to
only be used in the event that the door interlock fails to unlatch and the doors are unable to be opened.
1. To manually disengage, find the latch access hole.
2. Using a screwdriver, punch or even a metal utensil, gently insert the tip into the access hole, making contact with the latching
arm.
3. With a minimal amount of force, push the latching arm back, disengaging the interlock.
4. The doors should open now.