Tempstar HH Series Technical Manual 7610-002-23-32
Issued: 09/14/2007 Revised: N/A
SECTION 5: PARTS SECTION
SIDE MOUNT CONTROL BOX ASSEMBLY (CONTINUED)
23
ITEM
QTY
DESCRIPTION
Mfg. No.
1
1
Bracket, Electrical Box Mounting
05700-002-18-48
2
9
Locknut, 1/4"-20 S/S Hex with Nylon Insert
05310-374-01-00
3
9
Washer, 1/4"-20 I.D. S/S
05311-174-01-00
4
1
Control Box Weldment, Right Hand
05700-002-06-48
4
1
Control Box Weldment, Left Hand
05700-002-23-08
5
2
Contactor, 4 Pole 220V 1 Phase (Only 1 for No Booster and Steam Models)
05945-109-01-69
6
4
Screw, 10-32 x 1/2" Phillips Pan Head with Washer
05305-002-32-37
7
1
Liquid Level Control
06680-200-08-21
8
3
Screw, 6-32 x 5/8"
05305-011-39-85
9
1
Thermometer, 48 Lead, Wash
06685-111-68-48
1
Decal, Wash 150 Deg.
09905-002-97-61
10
1
Relay, 240V, 50/60HZ, Top Mount
05945-002-47-74
11
8
Screw, 6-32 x 3/8" SEMS with External Tooth Washer
05305-002-25-91
12
1
Decal, Control Box Gauge
09905-002-10-69
13
1
Thermometer, 96 Lead Rinse
06685-111-68-49
1
Decal, Rinse 180 Deg.
09905-002-97-62
14
1
Timer, 4CKT 208-230V Single REV (Shown)
05945-303-31-00
14
1
Timer, Universal
05945-003-07-48
1
Timer Bracket
05700-003-02-08
6
Holder, Keystone
05940-002-21-87
1
Keying Plug
05940-003-11-66
2
Connector
05940-003-11-65
15
1
Contactor, 2 Pole 220V 20AMP( 208-230 Volt Unit Only)
05945-002-74-20
16
3
Screw, 10-32 x 3/8" Phillips Pan Head
05305-173-26-00
17
1
Timer, Cycle Delay
05945-002-13-78
18
1
Terminal Block, 3 Pole
05940-011-48-27
19
1
Decal, L1, L2, L3
09905-101-12-66
20
1
Decal, Copper Conductors
09905-011-47-35
21
4
Locknut, 10-24 S/S Hex with Nylon Insert
05310-373-01-00
22
1
Wire Lug
05940-200-76-00
23
1
Decal, Ground
09905-011-86-86
24
1
Holder, Fuse
05920-401-03-14
25
1
Cover, Control Box Weldment
05700-002-06-52
26
4
Bolt, 10-32 x 1/2" Slotted Truss
05305-173-04-00
27*
1
Switch, 8 Button Tap Touch
05930-001-99-51
28*
1
Spacer, Switch Panel
05700-002-50-02
29
1
Decal, Control Box Cover
09905-002-00-45
30
1
Light, Red
05945-504-07-18
31
1
Light, Green Indicator
05945-504-08-18
32
1
Light, Amber
05945-504-06-18
33*
1
Cover, Dielectric Control Panel
05700-021-50-89
34
1
Contactor, 2 Pole 220V 20AMP (460 Volt Unit Only)
05945-002-65-00
35
1
Overload (460 Volt Unit Only)
05945-002-65-01
* Represents an item not shown.
Содержание TempStar HH
Страница 8: ...1 SECTION 1 SPECIFICATION INFORMATION ...
Страница 14: ...7 SECTION 2 INSTALLATION OPERATION INSTRUCTIONS ...
Страница 20: ...13 SECTION 3 PREVENTATIVE MAINTENANCE ...
Страница 22: ...15 SECTION 4 TROUBLESHOOTING ...
Страница 25: ...18 SECTION 5 PARTS SECTION ...
Страница 54: ...47 SECTION 6 ELECTRICAL SCHEMATICS ...
Страница 68: ...61 SECTION 7 JACKSON MAINTENANCE REPAIR CENTERS ...
Страница 75: ......