i

REVISION

REVISION

DATE

MADE

BY

APPLICABLE

ECN

DETAILS

F

06-01-04

MAW

N/A

Change to new layout.

G

05-20-05

MAW

N/A

Corrected amperage ratings, changed to thermostat bracket
05700-011-81-64, changed thermostat 05930-121-71-29 to ther-
mostat kit 06401-140-00-32, updated drawing for false panel
installation, and added SDI override instructions.

H

01-17-06

MAW

7609

Added universal timer, parts & schematics.

I

07-06-06

MAW

7713, 7571
7493, 7553

7411, 7422

7231

Updated specification & dimension pages. Updated drain quench
assembly. Replaced door switch 05930-003-02-20 with 05930-
003-05-84. Added false panel kit numbers, door component kits.
Replace ball stop components. Replace thermostat 05930-121-
71-29 with 05930-510-03-79. Added the wash & rinse thermome-
ter decals.

J

09-14-07

MAW

Obsoleting I/O manual, added warranty and repair centers info.
Listed minimum cycle times. Added Top Mount Control Box:
dimensions, hood weldment, control box, and schematics.
Corrected the rinse tank cover number, updated the cantilever
support bracket and reed switch numbers. 

Содержание TempStar HH

Страница 1: ...www jacksonmsc com TEMPSTAR HIGHER HOOD SERIES UPRIGHT DOOR DISHMACHINES September 14 2007 P N 7610 002 23 32 Revision J TECHNICAL MANUAL INSTALLATION MANUAL FOR EXPORT UNITS SERVICE MANUAL FOR DOMESTIC UNITS ELECTRICALLY HEATED MODELS TEMPSTAR HH TEMPSTAR HH NB STEAM HEATED MODELS TEMPSTAR HH S ...

Страница 2: ...on if serial number has been removed or altered or if unit is used for purpose other than it was origi nally intended TRAVEL LIMITATIONS Jackson MSC limits warranty travel time to 2 two hours and mileage to 100 one hundred miles Jackson MSC will not pay for travel time and mileage that exceeds this or any fees such as those for air or boat travel without prior authorization WARRANTY REGISTRATION C...

Страница 3: ... PRODUCT FAILURE TO DO SO WILL VOID THE WARRANTY LLAME AL 1 888 800 5672 PARA REGISTRAR ESTE PRODUCTO AL NO HACERLO LA GARANTIA SERA ANULADA S V P APPELER 1 888 800 5672 POUR ENREGISTRER CE PRODUIT LA GARANTIE SERA ANNULEE POUR TOUT PRODUIT NON ENREGISTREE ...

Страница 4: ...3 7571 7493 7553 7411 7422 7231 Updated specification dimension pages Updated drain quench assembly Replaced door switch 05930 003 02 20 with 05930 003 05 84 Added false panel kit numbers door component kits Replace ball stop components Replace thermostat 05930 121 71 29 with 05930 510 03 79 Added the wash rinse thermome ter decals J 09 14 07 MAW Obsoleting I O manual added warranty and repair cen...

Страница 5: ...with booster heater door type dishmachine with a higher hood TEMPSTAR HH NB Electrically heated hot water sanitizing no rinse booster door type dishmachine with a higher hood TEMPSTAR HH S Steam heated hot water sanitizing door type dishmachine with a higher hood Model Serial No Installation Date Service Rep Name Phone No ...

Страница 6: ...ount Control Box Assembly 22 Hood Assembly 24 Cantilever Arm Door Assemblies 25 Tub Assembly 27 Steam Tub Assembly 29 Frame Assembly 31 Rinse Tank Assembly 32 Steam Coil Assembly 33 Incoming Steam Plumbing Assemblies 34 Motors Wash Heaters Rinse Heaters 35 Incoming Plumbing Outlet Plumbing Assembly Tempstar HH 36 Incoming Plumbing Assembly Tempstar HH NB 38 Drain Quench Assembly 39 Solenoid Valve ...

Страница 7: ...ersal Timer 460 V 60 HZ three phase 53 Tempstar HH S Universal Timer 208 230 V 50 60 HZ single three phase 54 Tempstar HH 208 230 V 50 60 HZ single three phase 55 Tempstar HH 460 V 60 HZ three phase 56 Tempstar HH NB 208 230 V 50 60 HZ single three phase 57 Tempstar HH NB 460 V 60 HZ three phase 58 Tempstar HH S 208 230 V 50 60 HZ single three phase 59 Tempstar HH 415 V 50 HZ three phase 60 VIII M...

Страница 8: ...1 SECTION 1 SPECIFICATION INFORMATION ...

Страница 9: ... 0 NOTE Always refer to the machine data plate for specific electrical and water requirements The material provided on this page is for reference only and may be subject to change without notice WATER REQUIREMENTS TEMPSTAR HH WASH TEMPERATURE MINIMUM F 150 WASH TEMPERATURE MINIMUM C 66 RINSE TEMPERATURE MINIMUM F 180 RINSE TEMPERATURE MINIMUM C 83 INLET WATER TEMPERATURE 12KW RINSE HEATER F 140 12...

Страница 10: ...LTS PH HZ RATINGS AMPS CIRCUIT 208 1 60 N A 31 A 35 AMP 230 1 60 N A 33 A 35 AMP 208 3 60 N A 23 A 25 AMP 230 3 60 N A 24 A 35 AMP 460 3 60 N A 10 A 15 AMP TEMPSTAR HH S RINSE TYPICAL HEATER TOTAL ELECTRICAL VOLTS PH HZ RATINGS AMPS CIRCUIT 208 1 60 N A 12 A 15 AMP 230 1 60 N A 12 A 15 AMP 208 3 60 N A 12 A 15 AMP 230 3 60 N A 12 A 15 AMP NOTE Typical Electrical Circuit is based upon 1 125 of the ...

Страница 11: ...98mm Tempstar HH Series Technical Manual 7610 002 23 32 Issued 09 14 2007 Revised N A SECTION 1 SPECIFICATION INFORMATION TEMPSTAR HH DIMENSIONS TOP MOUNT CONTROL BOX 4 LEGEND A DRAIN 1 1 2 IPS B WATER INLET 3 4 IPS C ELECTRICAL CONNECTION All vertical dimensions are 1 2 due to adjustable bullet feet A 3 76mm 4 101mm 4 102mm B ...

Страница 12: ...IDE MOUNT CONTROL BOX 5 34 861mm 71 2 190mm 123 4 327mm 733 4 1876mm A 25 637mm 251 4 639mm B 1 27mm A 3 76mm 4 101mm 4 102mm 3 77mm 151 4 388mm 861 4 2190mm LEGEND A DRAIN 1 1 2 IPS B WATER INLET 3 4 IPS C ELECTRICAL CONNECTION All dimensions are in inches All vertical dimensions are 1 2 due to adjustable bullet feet B 12 1 4 310mm 27 687mm ...

Страница 13: ...SIONS 6 TABLE DIMENSIONS CORNER INSTALLATION TABLE DIMENSIONS CONNECTION TO DISHMACHINE TABLE DIMENSIONS STRAIGHT THROUGH INSTALLATION C OPENING D E A B A C OPENING D C G F ROLL A B D C OPENING D LETTER DIM IN DIM CM A 4 MIN 10 2 CM MIN B 2 1 2 6 4 CM C 20 1 2 52 1 CM D 25 1 4 64 1 CM E 2 1 4 10 2 CM F 1 1 2 3 8 CM G 3 4 1 9 CM ...

Страница 14: ...7 SECTION 2 INSTALLATION OPERATION INSTRUCTIONS ...

Страница 15: ...roughly flushed prior to connecting it to any com ponent of the dishmachine It is necessary to remove all foreign debris from the water line that may potentially get trapped in the valves or cause an obstruction Any valves that are fouled as a result of foreign matter left in the water line and any expenses resulting from this fouling are not the responsibility of the manufacturer CONNECTING THE D...

Страница 16: ...the service wires L1 L2 L3 three phase only to the appropriate ter minals as they are marked on the terminal block Install the grounding wire into the lug provided Tighten the connections It is recommended that DE OX or another similar anti oxidation agent be used on all power connections VOLTAGE CHECK Ensure that the power switch is in the OFF position and apply power to the dishmachine Check the...

Страница 17: ...r operators Using too much detergent has as detrimental effects as using too little The proper amount of detergent must be used for job It is important to remember that certain menu items may require extra detergent by their nature and personnel need to be made aware of this Experience in using the dishmachine under a variety of conditions along with good training in the operation of the machine c...

Страница 18: ... hold water during the cycle The dishmachine is meant not only to clean but to sanitize as well to destroy all of the bacteria that could be harmful to human beings In order to do this ware must be properly prepared prior to being placed in the machine DAILY MACHINE PREPARATION Refer to the section entitled PREPARATION at the top of this page and follow the instruc tions there Afterwards check tha...

Страница 19: ...d tight do not use tools to tighten them down Reinstall the drain stopper and strainers and close the doors WATER CONSUMPTION ISSUES AND EFFICIENCY The models covered in this manual provide you the customer with the ability to control the hourly rack capacity of the machine Extending the wash cycle to wash severely soiled ware such as mix ing bowls does not increase the machine s water consumption...

Страница 20: ...13 SECTION 3 PREVENTATIVE MAINTENANCE ...

Страница 21: ...earn more about how your water hardness will effect the performance of your machine Hard water makes dishmachines work harder and decreases efficiency Again it is important to remind operators that trying to perform corrective maintenance on the dishmachine could lead to larg er problems or even cause harm to the operator If a problem is discovered secure the dishmachine using proper shut down pro...

Страница 22: ...15 SECTION 4 TROUBLESHOOTING ...

Страница 23: ...s of the wash cycle The cycle delay timer will then cause the cam timer to stop in order to increase the length of the wash cycle The red light on the delay timer is in control of the cam timer If the red light is not turning on only during cycles B C or D replace the cycle timer 3 Wash cycle delay timer settings not correctly adjusted If the wash cycle delay timer and rotating cam timer are worki...

Страница 24: ... or pump drain if equipped not shut tight Close or tighten 3 Loose hoses hose clamps on the wash pump Tighten the hose clamps Problem Will not rinse during autocycle 1 Defective rinse solenoid Repair or replace the rinse solenoid as required 2 Faulty fill microswitch Replace microswitch 3 No water to the machine Verify that there is water at 20 5 PSI connected to the machine Problem Dishes are not...

Страница 25: ...18 SECTION 5 PARTS SECTION ...

Страница 26: ...ies Technical Manual 7610 002 23 32 Issued 09 14 2007 Revised N A SECTION 5 PARTS SECTION TOP MOUNT CONTROL BOX ASSEMBLY 19 10 8 1 44 For a 460V Unit Replace item 9 with items 45 46 47 Details for 460 Volt Control Box ...

Страница 27: ...Tempstar HH Series Technical Manual 7610 002 23 32 Issued 09 14 2007 Revised N A SECTION 5 PARTS SECTION TOP MOUNT CONTROL BOX ASSEMBLY CONTINUED 20 ...

Страница 28: ...5 002 97 62 21 1 Wire Lug 05940 200 76 00 22 1 Bracket Liquid Level Control Mounting 05700 002 13 22 23 1 Liquid Level Control 06680 200 08 21 25 3 Screw 6 32 x 5 8 05305 011 39 85 26 2 Spacer Switch Panel 05700 002 50 02 30 1 Clamp Nylon Hose 25 312 05975 002 61 43 31 1 Decal Warning Disconnect Power 09905 100 75 93 32 1 Cover Control Box 05700 002 23 03 33 1 Decal Control Box 09905 003 21 90 34 ...

Страница 29: ...sed N A SECTION 5 PARTS SECTION SIDE MOUNT CONTROL BOX ASSEMBLY 22 4 7 8 9 13 29 30 31 32 27 28 25 26 14 11 34 35 15 16 17 10 11 12 1 2 3 5 6 24 11 22 23 21 18 19 20 21 Represents an item not shown Details for 460V Control Box For a 460V Unit Replace item 15 with items 34 35 ...

Страница 30: ...4 1 Timer 4CKT 208 230V Single REV Shown 05945 303 31 00 14 1 Timer Universal 05945 003 07 48 1 Timer Bracket 05700 003 02 08 6 Holder Keystone 05940 002 21 87 1 Keying Plug 05940 003 11 66 2 Connector 05940 003 11 65 15 1 Contactor 2 Pole 220V 20AMP 208 230 Volt Unit Only 05945 002 74 20 16 3 Screw 10 32 x 3 8 Phillips Pan Head 05305 173 26 00 17 1 Timer Cycle Delay 05945 002 13 78 18 1 Terminal ...

Страница 31: ...4 01 00 4 26 Locknut 1 4 20 S S Hex with Nylon Inserts 05310 374 01 00 5 26 Bolt 1 4 20 x 1 2 Long Hex 05305 274 02 00 6 2 Right Left Front Outer Door Guide 05700 031 76 85 7 2 Right Left Front Inner Door Guide 05700 031 76 82 8 2 Right Left Front Hood Support Weldment 05700 002 17 68 9 1 Left Rear Outer Door Guide 05700 031 76 34 10 1 Left Rear Inner Door Guide 05700 031 76 33 11 1 Right Rear Out...

Страница 32: ...anual 7610 002 23 32 Issued 09 14 2007 Revised N A SECTION 5 PARTS SECTION CANTILEVER ARM DOOR ASSEMBLIES 17 18 35 24 33 34 6 3 4 5 2 1 7 28 27 22 29 30 31 32 26 25 4 5 23 4 24 10 9 19 20 17 18 36 22 21 22 8 11 13 12 14 15 16 12 25 ...

Страница 33: ...t Weldment 05700 002 29 59 18 4 Glide Upper Door 05700 002 00 83 1 Door Lower Right Assembly 05700 002 01 33 19 1 Door Lower Right 05700 031 76 80 20 2 Glide Lower Door 05700 002 23 64 21 1 Door Stop Magnet Assembly 06401 003 08 68 1 Door Stop Magnet Weldment 05700 002 01 27 1 Magnet 05930 111 69 25 2 End Cap 05700 011 60 92 22 6 Wear Button 05700 011 88 01 23 20 Screw 1 4 20 x 5 8 05305 274 24 00...

Страница 34: ...3 6 7 12 13 10 14 4 8 3 15 5 SEE PAGE ENTITLED WASH MOTORS 29 30 21 22 20 23 24 25 26 27 35 32 34 33 25 34 31 1 28 16 15 17 18 10 19 Nut 1 4 20 Serrated Nut 05310 011 66 49 Bracket Motor Support Weldment 05700 002 20 42 Pump Support Adjustable Bracket 05700 002 20 41 Represents an item not shown SEE PAGE ENTITLED WASH RINSE HEATERS ...

Страница 35: ...rge Hose 05700 011 88 24 17 1 Nipple 05700 021 34 84 18 1 Pump Support Bracket Assembly 05700 002 22 73 19 1 Clamp Hose 5 5 8 to 6 04730 011 34 90 20 1 Connector 1 2 90 05975 111 01 00 21 4 Nut 3 8 16 S S Hex 05310 276 01 00 22 4 Lockwasher 3 8 05311 276 01 00 23 1 High Water Probe 06680 200 02 68 24 1 Clamp 1 8 Nylon 05975 601 10 15 25 3 Locknut 6 32 with Nylon Insert 05310 373 03 00 26 4 Lockwas...

Страница 36: ...ASSEMBLY 29 12 10 11 2 3 4 7 8 13 14 11 15 5 9 3 16 6 22 23 21 24 25 27 28 26 1 29 17 16 18 19 20 Pump Support Bracket Complete Assembly 05700 002 00 46 Nut 1 4 20 Serrated Nut 05310 011 66 49 Bracket Motor Support Weldment 05700 002 68 31 Pump Support Adjustable Bracket 05700 002 20 41 Represents an item not shown ...

Страница 37: ...Weldment 05700 021 50 07 13 1 Wash Overflow Weldment 05700 001 25 69 1 Support Ball Stop Lift 05700 002 91 55 1 Ball Stop Lift 05700 003 07 50 14 1 Overflow Support Bracket 05700 001 27 55 15 1 O Ring 05330 400 05 00 16 2 Clamp Hose 1 5 16 to 2 1 4 04730 719 01 37 17 1 Discharge Hose 05700 011 88 24 18 1 Nipple 05700 021 34 84 19 1 Pump Support Bracket Assembly 05700 002 00 46 20 1 Clamp Hose 5 5 ...

Страница 38: ...ed 09 14 2007 Revised N A SECTION 5 PARTS SECTION FRAME ASSEMBLY 31 Bullet Foot 05340 108 02 06 Bullet Foot 415V 05340 002 14 55 Flange Feet 05340 002 01 15 Cover Front Panel 05700 002 01 42 Frame Weldment 05700 002 03 49 Frame Weldment 415V 05700 002 62 41 ...

Страница 39: ...ecal Warning Disconnect Power 09905 100 75 93 5 1 Booster Tank Cover Weldment 05700 002 16 51 6 6 Nut Hex 5 16 18 05310 275 01 00 7 1 Thermostat High Limit 05930 011 49 43 8 1 Thermostat Regulating with Imperial Brass Fitting 06401 011 66 55 9 6 Lockwasher 5 16 Split 05311 275 01 00 10 1 Gasket Rinse Heater 05330 200 02 70 11 4 Locknut 1 4 20 with Nylon Insert 05310 374 01 00 12 4 Washer 1 4 S S F...

Страница 40: ...Steam Coil Weldment 05700 021 41 38 Stand D Steam Coil Support 05700 002 08 53 Stand B Steam Coil Support 05700 002 08 51 Adapter Steam Coil Nut 2 per assembly 05310 011 17 85 Washer Steam Coil 2 per assembly 05700 001 17 87 Gasket Steam Coil 4 per assembly 05700 001 17 86 Stand A Steam Coil Support 05700 002 08 50 Complete Steam Coil Assembly 05700 002 08 62 33 ...

Страница 41: ...730 907 01 00 Nipple Close 3 4 NPT Black Iron 4 per assembly 04730 907 01 00 Bushing Reducing 3 4 to 1 2 04730 911 02 34 Bushing Reducing 3 4 to 1 2 04730 911 02 34 Union 3 4 NPT Black Iron 2 per assembly 04730 912 01 01 3 4 NPT Black Iron Pipe 05700 002 20 83 Gate Valve 3 4 NPT 04820 100 19 00 Bracket Steam Plumbing Support 05700 002 20 83 Y Strainer 3 4 NPT Black Iron 04730 217 01 32 Solenoid Va...

Страница 42: ...t using the same wires Always refer to the wiring diagrams on the motor you are installing If the motor you are installing has had the schemat ic removed contact Jackson MSC immediately for technical support The Tempstar models covered in this manual come supplied with various heaters depending on the characteristics of the machine To ensure that you order the correct heater for the model you are ...

Страница 43: ...nical Manual 7610 002 23 32 Issued 09 14 2007 Revised N A SECTION 5 PARTS SECTION INCOMING OUTLET PLUMBING ASSEMBLIES 36 INCOMING PLUMBING OUTLET PLUMBING 15 4 9 10 16 1 7 3 2 6 5 4 4 8 9 10 11 13 12 10 17 13 9 18 13 14 12 10 ...

Страница 44: ...Tube Copper 3 4 x 44 3 8 Long 05700 002 25 05 17 1 Elbow 3 4 90 Copper to FSPS Brass 04730 406 41 01 18 1 Elbow 3 4 90 Copper to Copper Street 04730 406 40 01 19 2 Double Pipe Clamp 05700 002 23 89 20 1 Bracket Incoming Plumbing Support 05700 021 34 02 When servicing plumbing components take care not to damage the threads of each individual item Damaged threads can cause leaks and loss of pressure...

Страница 45: ... 3 4 NPT 04730 206 04 34 3 1 Nipple Brass 3 4 NPT x 3 Long 04730 011 38 29 4 1 Union 3 4 NPT Brass with O ring 05700 002 63 79 5 3 Nipple Close Brass 3 4 NPT 04730 207 34 00 6 1 Valve Solenoid 3 4 NPT 04810 100 03 18 7 1 Tee Brass 3 4 NPT x 3 4 NPT x 1 4 NPT 04730 211 04 00 8 1 Pressure Gauge 0 100 PSI 06685 111 59 66 9 1 Valve Ball Bronze 1 4 NPT 04810 011 72 67 10 1 Water Pressure Regulator 0668...

Страница 46: ...d Compression Fitting as required Attach to the incoming cold water line Use pipe dope or thread tape as required to prevent any leaks Thermostat 05930 003 13 65 Solenoid Valve 04810 100 09 18 To Cold Water Supply Nipple Close 1 2 NPT Not Shown 04730 207 15 00 Valve Check 1 2 Not Shown 04820 002 55 77 Lid Drain Quench 05700 002 67 16 Box Drain Quench 05700 002 69 96 Reducer 1 1 2 to 1 2 04730 002 ...

Страница 47: ... Bonnet Spring 06401 003 07 40 Plunger 06401 003 07 40 O Ring 06401 003 07 42 Diaphragm Retainer Diaphragm 06401 003 07 42 Screen Retainer Mesh Screen Valve Body Complete 240 Volt Solenoid Valve Assembly 04810 100 03 18 Coil Housing only 06401 003 07 44 Complete Vacuum Breaker Assembly 04820 002 53 77 Components of Repair Kit 06401 003 06 24 Cap Screw Data Plate Cap O Ring Plunger Body Cap Retaine...

Страница 48: ...2 Issued 09 14 2007 Revised N A SECTION 5 PARTS SECTION WASH RINSE ARM MANIFOLD ASSEMBLIES 41 13 16 19 14 11 12 15 15 2 3 4 5 7 17 8 6 18 5 9 7 1 DETAIL B WASH ARMS MANIFOLD DETAIL A FINAL RINSE ARMS MANIFOLD 18 18 18 18 5 10 21 17 2 3 19 5 21 9 18 1 ...

Страница 49: ...5700 021 35 93 10 1 Bearing Assembly 05700 021 35 97 1 O ring 05330 002 60 69 1 Wash Arm Assembly 415V 05700 021 63 81 9 1 Wash Arm Weldment 415V 05700 021 63 42 10 1 Bearing Assembly 415V 05700 021 63 80 2 Rinse Arm Assembly 05700 002 58 09 11 2 Clip Retaining Rinse Head Bushing 05340 112 01 11 12 4 Washer 05330 011 42 10 13 2 Bushing Rinse Head 05700 021 33 84 14 2 Rinse Arm 05700 031 49 58 15 4...

Страница 50: ... SECTION 5 PARTS SECTION 460 VOLT MACHINE TRANSFORMER MOUNTING BOX 460V Transformer 05950 111 65 93 2 Amp Circuit Breaker 05925 111 64 18 Transformer Mounting Bracket 05700 031 62 82 Transformer Mounting Box 05700 002 10 01 Transformer Mounting Box Top not shown 05700 000 78 53 43 ...

Страница 51: ...ock Option 04810 100 61 33 Relay 05945 111 47 51 Latch access hole The following instructions are for Tempstar HH models equipped with the Safety Door Interlock option These instructions are to only be used in the event that the door interlock fails to unlatch and the doors are unable to be opened 1 To manually disengage find the latch access hole 2 Using a screwdriver punch or even a metal utensi...

Страница 52: ...HH Series Technical Manual 7610 002 23 32 Issued 09 14 2007 Revised N A SECTION 5 PARTS SECTION EXHAUST FAN CONTROL OPTION 45 Delay Timer 05945 011 65 44 2 Din Rail 05700 002 36 09 Terminal Board 05940 011 84 41 ...

Страница 53: ...f the dishmachine and push upward 5 The panel will clip in at the top inside of the unit 6 The holes in the false panel will line up with the rack assembly holes 7 Re install the screws for the rack assembly which will secure the false panel to the unit 8 Re assemble the rack track in an L shape for a corner operation Bottom of False Panel Insert this side first False Panel Positioned in unit Rack...

Страница 54: ...47 SECTION 6 ELECTRICAL SCHEMATICS ...

Страница 55: ...Tempstar HH Series Technical Manual 7610 002 23 32 Issued 09 14 2007 Revised N A SECTION 6 ELECTRICAL SCHEMATICS TEMPSTAR HH TOP MOUNT CONTROLS 208 230 VOLT 60 HERTZ SINGLE THREE PHASE 48 ...

Страница 56: ...Tempstar HH Series Technical Manual 7610 002 23 32 Issued 09 14 2007 Revised N A SECTION 6 ELECTRICAL SCHEMATICS TEMPSTAR HH TOP MOUNT CONTROLS 460 VOLT 60 HERTZ THREE PHASE 49 ...

Страница 57: ...Tempstar HH Series Technical Manual 7610 002 23 32 Issued 09 14 2007 Revised N A SECTION 6 ELECTRICAL SCHEMATICS TEMPSTAR HH UNIVERSAL TIMER 208 230 VOLT 60 HERTZ SINGLE THREE PHASE 50 ...

Страница 58: ...Tempstar HH Series Technical Manual 7610 002 23 32 Issued 09 14 2007 Revised N A SECTION 6 ELECTRICAL SCHEMATICS TEMPSTAR HH UNIVERSAL TIMER 460 VOLT 60 HERTZ THREE PHASE 51 ...

Страница 59: ...Tempstar HH Series Technical Manual 7610 002 23 32 Issued 09 14 2007 Revised N A SECTION 6 ELECTRICAL SCHEMATICS TEMPSTAR HH NB HH LT UNIVERSAL TIMER 208 230 VOLT 60 HERTZ SINGLE THREE PHASE 52 ...

Страница 60: ...Tempstar HH Series Technical Manual 7610 002 23 32 Issued 09 14 2007 Revised N A SECTION 6 ELECTRICAL SCHEMATICS TEMPSTAR HH NB HH LT UNIVERSAL TIMER 460 VOLT 60 HERTZ THREE PHASE 53 ...

Страница 61: ...Tempstar HH Series Technical Manual 7610 002 23 32 Issued 09 14 2007 Revised N A SECTION 6 ELECTRICAL SCHEMATICS TEMPSTAR HH S UNIVERSAL TIMER 208 230 VOLT 60 HERTZ SINGLE THREE PHASE 54 ...

Страница 62: ...Tempstar HH Series Technical Manual 7610 002 23 32 Issued 09 14 2007 Revised N A SECTION 6 ELECTRICAL SCHEMATICS TEMPSTAR HH 208 230 VOLT 60 HERTZ SINGLE THREE PHASE 55 ...

Страница 63: ...Tempstar HH Series Technical Manual 7610 002 23 32 Issued 09 14 2007 Revised N A SECTION 6 ELECTRICAL SCHEMATICS TEMPSTAR HH 460 VOLT 60 HERTZ THREE PHASE 56 ...

Страница 64: ...LOCK S1 POWER SWITCH S2 DOOR SWITCH S3 AUTO MANUAL DELIME SWITCH S4 SELECTOR SWITCH CYCLE 4 S5 SELECTOR SWITCH CYCLE 3 S6 SELECTOR SWITCH CYCLE 2 S7 SELECTOR SWITCH CYCLE 1 C1 CYCLE SWITCH C2 AUTO START RESET SWITCH C3 WASH CYCLE SWITCH C4 RINSE FILL SWITCH E1 POWER LIGHT E2 HEATER OVERLOAD LIGHT E3 CYCLE LIGHT HLTS WASH HEATER HIGH LIMIT T STAT TS1 WASH HEATER THERMOSTAT GND GROUND HP HIGH WATER ...

Страница 65: ...Tempstar HH Series Technical Manual 7610 002 23 32 Issued 09 14 2007 Revised N A SECTION 6 ELECTRICAL SCHEMATICS TEMPSTAR HH NB HH LT 460 VOLT 60 HERTZ THREE PHASE 58 ...

Страница 66: ...Tempstar HH Series Technical Manual 7610 002 23 32 Issued 09 14 2007 Revised N A SECTION 6 ELECTRICAL SCHEMATICS TEMPSTAR HH S 208 230 VOLT 60 HERTZ SINGLE THREE PHASE 59 ...

Страница 67: ...Tempstar HH Series Technical Manual 7610 002 23 32 Issued 09 14 2007 Revised N A SECTION 6 ELECTRICAL SCHEMATICS TEMPSTAR HH 415 VOLT 50 HERTZ THREE PHASE 60 09905 002 32 44C ...

Страница 68: ...61 SECTION 7 JACKSON MAINTENANCE REPAIR CENTERS ...

Страница 69: ...4 FAX 650 635 1919 pndappl aol com P D APPLIANCE 4220 C ROSEVILLE ROAD NORTH HIGHLANDS CA 95660 916 974 2772 800 824 7219 FAX 916 974 2774 COMMERCIAL APPLIANCE SERVICE INC 281 LATHROP WAY 100 SACRAMENTO CA 95815 916 567 0203 800 464 2222 916 567 0324 FAX COLORADO GCS SERVICE INC SHERIDAN CO 303 371 9054 800 972 5314 FAX 303 371 4754 HAWKINS COMMERCIAL APPLIANCE SERVICE 3000 S WYANDOT ST ENGLEWOOD ...

Страница 70: ...POLIS IN 317 545 9655 800 727 8710 FAX 317 549 6286 B622 LA PAS TRAIL INDIANAPOLIS IN 46268 317 290 8060 800 410 9794 317 290 8085 FAX IOWA GOODWIN TUCKER GROUP 2900 DELAWARE AVENUE DES MOINES IA 50317 515 262 9308 800 372 6066 FAX 515 262 2936 parts goodwintucker com CONES REPAIR SVC 1056 27TH AVENUE SW CEDAR RAPIDS IA 52404 319 365 3325 800 747 3326 FAX 319 365 0885 KANSAS GCS SERVICE INC KANSAS...

Страница 71: ...284 4427 FAX 314 638 0135 KAEMMERLIN PARTS SVC 2728 LOCUST STREET ST LOUIS MO 63103 314 535 2222 FAX 314 535 6205 petek kps stl com GENERAL PARTS INC 1101 EAST 13TH STREET KANSAS CITY MO 64106 816 421 5400 800 279 9967 816 421 1270 FAX MONTANA RESTAURANT APPLIANCE SVC 7219 ROOSEVELT WAY NE SEATTLE WA 98115 206 524 8200 800 433 9390 FAX 206 525 2890 info restappl com NEBRASKA GOODWIN TUCKER GROUP 7...

Страница 72: ...O ND 58103 701 235 4161 800 279 9987 701 235 0539 FAX OHIO CERTIFIED SERVICE CENTER 890 REDNA TERRACE CINCINNATI OH 45215 513 772 6600 800 543 2060 FAX 513 612 6600 sbarasch certifiedsc com CERTIFIED SERVICE CENTER 171J K NORTH HAMILTON RD COLUMBUS OH 43213 614 751 3769 866 862 1252 FAX 614 751 5792 jadkins certifiedsc com CERTIFIED SERVICE CENTER 6025 N DIXIE DRIVE DAYTON OH 45414 937 898 4040 80...

Страница 73: ...00 442 5026 FAX 972 484 2531 GCS SERVICE INC HOUSTON TX 713 785 9187 800 868 6957 FAX 713 785 3979 GCS STOVE PARTS 2120 SOLANA STREET FORT WORTH TX 76117 817 831 0381 800 433 1804 FAX 817 834 7754 bud stoveparts com UTAH LA MONICA S RESTAURANT EQMT SVC 6182 SOUTH STRATLER AVENUE MURRAY UT 84107 801 263 3221 800 527 2561 FAX 801 263 3229 lamonica81 aol com VERMONT NORTHERN PARTS SVC 4874 S CATHERIN...

Страница 74: ...2 FAX 303 778 0268 metroappls aol com INTERNATIONAL GLOBAL PARTS AND SUPPLY 7758 NW 72ND ST MIAMI FL 33166 305 885 6353 H D SHELDON AND CO 19 UNION SQUARE WEST NEW YORK NY 10003 212 627 1759 212 924 6920 CANADA THE GARLAND GROUP 1177 KAMATO ROAD MISSISSAUGA ONTARIO L4W 1X4 905 206 8380 SALES 905 624 1419 FAX 905 624 1851 SERVICE 800 427 6668 FAX 800 361 7745 Tempstar HH Series Technical Manual 761...

Страница 75: ......

Отзывы: