U01

,通过左移键(

)和右移键(

)修改参数项,按上移键(

)和下移键(

修改相应参数的值,设置完按

P

键(

)进行确认保存,

5S

无按键则不保存退到待机界

面。

 

Press the combination button P 

+down button

  for about 1.5 seconds, and it will enter the 

technician parameter adjustment mode, display U01, modify the parameter items by left button

 and right 

button

, press up button

  and down button

  to modify the value of the corresponding 

parameters, set up and press P button

  for confirmation and preservation, and 5S button-free will not be 

saved back to be waiting machine interface. 

2.7

 

恢复出厂设置  Restore factory setting 

按复位键(

1.5

秒参数将恢复用户保存参数,参数范围为用户参数与技术员参

数。按左移键(

)和右移键(

)约

1.5

秒,恢复出厂参数、恢复关联参数。(

P21 = 

1

时按

P

键保存一组用户常用参数,复位键恢复用户保存参数,未保存前出厂参数与用户保

存区参数相同。

P19/P20

版本号参数、

P66/P67/P68

转接板占空比参数、

P73

出厂默认转速参

数、

P90

监控查看使能参数、

P94/P95

机型选择参数等不恢复出厂设置)。

 

Press reset button

for 1.5 seconds ,Parameters will restore users saving Parameters. Parameters range from 

uses parameter to technician parameter, Press left button

and right button

together for 1.5 seconds, 

Parameter will restore factory parameters .and associated parameters.when P21=1,P button for saving users 
common parameters, reset button for restoring users saving parameters, before saving, factory parameters are the 
same as users saving parameters,P19/P20 version no. Parameter,P66/P67/P68 the duty cycle parameters of the 
adapter board, P73 the default speed parameters of factory, P90 monitoring and checking parameters.P94/P95 
model selection parameter can not reset to the factory setting.

 

2.8

 

语音种类设置 Voice Language Setting 

按左移键(

)切换语音种类,左键按下后,播报当时所选的语音种类,按

P

键(

确定,更改语音种类。

 

Press the left shift key (

) to switch the voice type. When the left button is pressed, the voice 

type selected at that time is broadcasted. Press the P key (

) to confirm and change the voice 

type. 

2.9

 

穿线灯开关的设置  LED light setting 

穿线灯亮度分为四档,在待机显示界面,按右移键(

)穿线灯光亮度在

4

个档位间

循环调节。(其中一个档位为关闭)

 

LED light is divided into four gears, On the standby interface ,Press right button

, LCD light 

brightness will be cycled in four modes.(one is off)

 

2.10

 

按键锁定设置  Button lock setting 

更改参数项

P62

1

时,锁定按键后,按键动作无响应。长按剪线参数设置键(

1.5

秒解除锁定,按键恢复使用。

 

When modifying parameter P62 to 1,button will be locked and no response. Long Press trimmer parameter

for 1.5 seconds will cancel the lock setting. press restore used.

 

2.11

 

语音快捷开关      Voice quick switch 

长按语音导航键(

1.5s

,进行语音开关切换。短按语音键进行开机欢迎语音开关

Содержание C5

Страница 1: ...C5 V1 8 Instructions of C5 overlock sewing machine panel operation 2020 6 1 EC5...

Страница 2: ...e Setting 4 2 9 LED light setting 4 2 10 Button lock setting 4 2 11 Voice quick switch 4 2 12 Sensor for anti cutting the cloth swift switch 5 2 13 Forced removal of cloth piece value 5 2 14 Fabric se...

Страница 3: ...ase the number within a parameter 5 Right button control machine head LCD light brightness Towards the right to choose parameter within a parameter 6 Sewing mode button Change the sewing mode 7 Presse...

Страница 4: ...be cycled as following three modes Automatic Semi automatic Full manual Press enter mode to confirm and save after finishing setting No Pressing for 5 seconds return to standby interface if user does...

Страница 5: ...ter button to save and confirm after finishing setting No Pressing for 5 seconds return to standby interface if user doesn t want to save every press enter the current trimmer status firstly and cycle...

Страница 6: ...ng users common parameters reset button for restoring users saving parameters before saving factory parameters are the same as users saving parameters P19 P20 version no Parameter P66 P67 P68 the duty...

Страница 7: ...rameter values to change then the P28 parameter is equal to the user saves parameter values 5 When entering the other interface without saving and don t press any key for 5 seconds will automatically...

Страница 8: ...h sensor enabled state changes the sensor will be automatically calibrated 2 16 Thick material voltage threshold setting 1 5 P U15 OK Er P 50 U16 PA2 1 1 5 Press the presser foot lifter for about 1 5...

Страница 9: ...er values of PA0 PA1 Note Normal sewing can be done during regular maintenance reminder 2 19 Short thread mode quick switch 3s OK P27 U25 Press the short thread button for 3 seconds to switch the shor...

Страница 10: ...erized 1 semi automatic 2 fully automatic P6 Voice volume adjustment 0 3 2 0 1 3 0 off 1 3 on P7 Auto trimming 0 3 3 0 1 2 3 0 off 1 trimmer before sewing 2 trimmer after sewing 3 trimmer both before...

Страница 11: ...n 0 250 0 0 100 ms Time when front suction off 0 is not off 100 ms P25 Back sensor switch 0 1 1 0 1 0 off 1 on P Technician parameter At the same time press the P button and the presser foot lifter bu...

Страница 12: ...r foot lifter 1 50 2 100ms P40 Start time after presser foot lifter 0 20 0 100 ms P41 Full output time of presser foot 1 50 10 10 ms P42 Periodic signal of presser foot output 0 50 15 10 ms 5MS Turn o...

Страница 13: ...tage value of the sensor P68 Adjusting gear of sensor for anti cutting the cloth 1 180 The greater the parameter values The greater the voltage value of the sensor P69 Unit number counting 1 50 10 1 S...

Страница 14: ...hread number closing P82 Synchronized suction back suction closed needle number 0 250 0 0 P82 0 Back suction and back trimmer synchronous closing Other when after front suction opening go by P82 threa...

Страница 15: ...Unit month 0 1 500 0 not enable 1 500 reminder time P102 Base enable of thick material 0 1 0 1 1 Automatic acquisition of base value when thickness enters the threshold setting of thick material P112...

Страница 16: ...function is turned off duty cycle decreases from 100 to U28 setting value uniformly in 1 U29 time duty cycle decreases from U28 to U31 setting value uniformly in 2 U29 time and 3 U28 duty cycle is con...

Страница 17: ...e Please try to restore the factory settings or restart the power supply If the above can not be solved please contact the local service provider or dial 4008876858 Pressing the P key or the voice key...

Страница 18: ...solve the problem please contact with the local agent or call 4008876858 E9 Pedal connection abnormal 4008876858 Please check whether the pedal plug is connecting with control box or not or loosening...

Страница 19: ...Voltage foot electromagnet control fault EA1 The ascending count is full P P71 5 Press P to clear or change value to 5 in parameter P71 EA2 The descending count is full P P71 5 Press P to clear or ch...

Страница 20: ...l and panel program to a matching program A 09 White grease regular maintenance warning A 10 Regular cleaning warning 7 Speed controller 1 4 ST4 8 2 Use four pieces ST4 8tapping screw Part No 2 to ins...