background image

 

时,修改的是剪线吸风模式、前剪线吸风关闭针数

P30

或后剪线吸风关闭延时

P31

参数。

连续按此键时,参数项循环如下:前剪线(吸风)开、后剪线(吸风)开、前后剪线(吸风)
开、关闭、前剪线延迟针数

/

前剪线吸风关闭针数、后剪线延迟针数(防切布传感器延迟针

数)

/

后剪线吸风关闭延时,按上移键(

)和下移键(

)修改相应参数的值,设置

完后按

P

键(

)进行确认保存,

5S

无按键则不保存退到待机界面。(每次按键先进入

当前剪线状态,按以上顺序循环)

 

Press trimmer parameter setting button

 

to modify parameter for trimmer status;when 

P94=0/1,it 

is to modify trimmer mode P7,and the delay stitches number of trimmer before sewing P27 or the delay stitches 
number of trimmer after sewing P28(The delay stitches number of anti-cutting cloth sensor P50).When

P94=2, 

It is modify for trimmer suction mode,front trimmer suction closed needle number P30 or back trimmer suction 
close delay P31.Continuous press down this button, sewing mode will be cycled as followings: trimmer and 
suction before sewing on

trimmer and suction after sewing on

trimmer and suction both before and after sewing 

on

off

delay stitches number of trimmer before sewing

the delay stitches number of trimmer after sewing

the 

delay stitches number of sensor for anti-cutting the cloth

Press up button

 

and down button

 

to modify the value of the corresponding parameter

enter button

 

to save and confirm after finishing 

setting. No Pressing for 5 seconds return to standby interface if user doesn

t want to save..(every press enter the 

current trimmer status firstly and cycled as below).

 

2.4

 

转速的修改  Modify speed 

在待机界面按上移键(

)和下移键(

)可以快速调整最高转速值,按上移键

)递增

100 RPM

,按下移键(

)递减

100 RPM

。设置完按

P

键(

)进行确认

保存,

5S

无按键则不保存退到待机界面。

 

Press the up button

and down button

in standby interface can rapidly adjust the highest speed 

value. Press up button

increases 100 RPM while press down button

decreases 100 RPM. After 

finishing settings, press enter button

  to save the parameter. If customer doesn

t want to save, No Pressing 

for 5 seconds back to standby interface if user doesn

t want to save. 

 

2.5

 

技术区参数的修改  Change technician parameter 

按组合键

P

键(

 + 

抬压脚键(

)约

1.5

秒,将进入技术员参数调整模式,

显示

P26

,通过左移键(

)和右移键(

)修改参数项,按上移键(

)和下移键

)修改相应参数的值,设置完按

P

键(

)进行确认保存,

5S

无按键则不保存退

到待机界面。

 

Press button

  and enter button

together for 1.5 seconds

the machine will enter the technician 

parameter adjustment mode and the panel will display P26.Press left button

and right button

to 

change the parameter. Press up button

and down button

to modify the value of corresponding 

parameter. Press enter button (

) to confirm and save No Pressing for 5 seconds back to standby interface if 

user doesn

t want to save. 

 

2.6

 

工艺区参数的修改  Change technician parameter 

按组合键

P

键(

  +

下移键(

)约

1.5

秒,将进入工艺区参数调整模式,显

Содержание C5

Страница 1: ...C5 V1 8 Instructions of C5 overlock sewing machine panel operation 2020 6 1 EC5...

Страница 2: ...e Setting 4 2 9 LED light setting 4 2 10 Button lock setting 4 2 11 Voice quick switch 4 2 12 Sensor for anti cutting the cloth swift switch 5 2 13 Forced removal of cloth piece value 5 2 14 Fabric se...

Страница 3: ...ase the number within a parameter 5 Right button control machine head LCD light brightness Towards the right to choose parameter within a parameter 6 Sewing mode button Change the sewing mode 7 Presse...

Страница 4: ...be cycled as following three modes Automatic Semi automatic Full manual Press enter mode to confirm and save after finishing setting No Pressing for 5 seconds return to standby interface if user does...

Страница 5: ...ter button to save and confirm after finishing setting No Pressing for 5 seconds return to standby interface if user doesn t want to save every press enter the current trimmer status firstly and cycle...

Страница 6: ...ng users common parameters reset button for restoring users saving parameters before saving factory parameters are the same as users saving parameters P19 P20 version no Parameter P66 P67 P68 the duty...

Страница 7: ...rameter values to change then the P28 parameter is equal to the user saves parameter values 5 When entering the other interface without saving and don t press any key for 5 seconds will automatically...

Страница 8: ...h sensor enabled state changes the sensor will be automatically calibrated 2 16 Thick material voltage threshold setting 1 5 P U15 OK Er P 50 U16 PA2 1 1 5 Press the presser foot lifter for about 1 5...

Страница 9: ...er values of PA0 PA1 Note Normal sewing can be done during regular maintenance reminder 2 19 Short thread mode quick switch 3s OK P27 U25 Press the short thread button for 3 seconds to switch the shor...

Страница 10: ...erized 1 semi automatic 2 fully automatic P6 Voice volume adjustment 0 3 2 0 1 3 0 off 1 3 on P7 Auto trimming 0 3 3 0 1 2 3 0 off 1 trimmer before sewing 2 trimmer after sewing 3 trimmer both before...

Страница 11: ...n 0 250 0 0 100 ms Time when front suction off 0 is not off 100 ms P25 Back sensor switch 0 1 1 0 1 0 off 1 on P Technician parameter At the same time press the P button and the presser foot lifter bu...

Страница 12: ...r foot lifter 1 50 2 100ms P40 Start time after presser foot lifter 0 20 0 100 ms P41 Full output time of presser foot 1 50 10 10 ms P42 Periodic signal of presser foot output 0 50 15 10 ms 5MS Turn o...

Страница 13: ...tage value of the sensor P68 Adjusting gear of sensor for anti cutting the cloth 1 180 The greater the parameter values The greater the voltage value of the sensor P69 Unit number counting 1 50 10 1 S...

Страница 14: ...hread number closing P82 Synchronized suction back suction closed needle number 0 250 0 0 P82 0 Back suction and back trimmer synchronous closing Other when after front suction opening go by P82 threa...

Страница 15: ...Unit month 0 1 500 0 not enable 1 500 reminder time P102 Base enable of thick material 0 1 0 1 1 Automatic acquisition of base value when thickness enters the threshold setting of thick material P112...

Страница 16: ...function is turned off duty cycle decreases from 100 to U28 setting value uniformly in 1 U29 time duty cycle decreases from U28 to U31 setting value uniformly in 2 U29 time and 3 U28 duty cycle is con...

Страница 17: ...e Please try to restore the factory settings or restart the power supply If the above can not be solved please contact the local service provider or dial 4008876858 Pressing the P key or the voice key...

Страница 18: ...solve the problem please contact with the local agent or call 4008876858 E9 Pedal connection abnormal 4008876858 Please check whether the pedal plug is connecting with control box or not or loosening...

Страница 19: ...Voltage foot electromagnet control fault EA1 The ascending count is full P P71 5 Press P to clear or change value to 5 in parameter P71 EA2 The descending count is full P P71 5 Press P to clear or ch...

Страница 20: ...l and panel program to a matching program A 09 White grease regular maintenance warning A 10 Regular cleaning warning 7 Speed controller 1 4 ST4 8 2 Use four pieces ST4 8tapping screw Part No 2 to ins...

Отзывы: