Jack C5 Скачать руководство пользователя страница 2

 

 

目    录 

Catalogue 

1.

 

显示及操作界面  Display and operation menu

 

........................................................

 

1

 

1.1

 

显示界面介绍  Operation Panel Instructions

 

...........................................................

 

1

 

1.2

 

按键设置介绍  Button setting Instructions

 

...............................................................

 

2

 

2.

 

常用参数设置  Common parameters setting

 

...........................................................

 

2

 

2.1

 

全智能/半智能/全电脑模式的设置 Automatic/  Semi‐automatic/  Full  manual 

mode settings

 

..............................................................................................................................

 

2

 

2.2

 

抬压脚模式的设置  Presser foot lifter mode setting

 

..............................................

 

2

 

2.3

 

剪线参数的设置    Trimmer parameter setting

 

.........................................................

 

2

 

2.4

 

转速的修改  Modify speed

 

.............................................................................................

 

3

 

2.5

 

技术区参数的修改  Change technician parameter

 

..................................................

 

3

 

2.6

 

工艺区参数的修改  Change technician parameter

 

..................................................

 

3

 

2.7

 

恢复出厂设置  Restore factory setting

 

.......................................................................

 

4

 

2.8

 

语音种类设置 Voice Language Setting

 

.......................................................................

 

4

 

2.9

 

穿线灯开关的设置  LED light setting

 

............................................................................

 

4

 

2.10

 

按键锁定设置  Button lock setting

 

..............................................................................

 

4

 

2.11

 

语音快捷开关      Voice quick switch

 

............................................................................

 

4

 

2.12

 

防切布传感器快捷开关  Sensor for anti‐cutting the cloth swift switch

 

...........

 

5

 

2.13

 

布料计件值强制清除  Forced removal of cloth piece value

 

..................................

 

5

 

2.14

 

面料选择    Fabric selection

 

............................................................................................

 

5

 

2.15

 

传感器自动校准  Sensor automatic calibration

 

.......................................................

 

6

 

2.16

 

厚料电压阈值设定    Thick material voltage threshold setting

 

...........................

 

6

 

2.17

 

短线头面料设置  Short thread fabric setting

 

...........................................................

 

6

 

2.18

 

定期保养  Regular maintenance

 

..................................................................................

 

7

 

2.19

 

短线头模式快捷开关  Short thread mode quick switch

 

.........................................

 

7

 

3

 

数码管显示说明  Digital tube display Instructions

 

.................................................

 

7

 

4

 

参数列表      Parameters list

 

...........................................................................................

 

8

 

4.1

 

操作参数说明表    Operating parameters Instructions

 

..........................................

 

8

 

4.2

 

监控参数    Monitoring parameters

 

..........................................................................

 

14

 

5

 

错误码说明表   

   

  Error Code Instructions

 

............................................................

 

15

 

6

 

警告码说明表    Warning Code Instructions

 

...........................................................

 

17

 

7

 

调速器

 

Speed

 

controller

 

...................................................................................................

 

18

 

Содержание C5

Страница 1: ...C5 V1 8 Instructions of C5 overlock sewing machine panel operation 2020 6 1 EC5...

Страница 2: ...e Setting 4 2 9 LED light setting 4 2 10 Button lock setting 4 2 11 Voice quick switch 4 2 12 Sensor for anti cutting the cloth swift switch 5 2 13 Forced removal of cloth piece value 5 2 14 Fabric se...

Страница 3: ...ase the number within a parameter 5 Right button control machine head LCD light brightness Towards the right to choose parameter within a parameter 6 Sewing mode button Change the sewing mode 7 Presse...

Страница 4: ...be cycled as following three modes Automatic Semi automatic Full manual Press enter mode to confirm and save after finishing setting No Pressing for 5 seconds return to standby interface if user does...

Страница 5: ...ter button to save and confirm after finishing setting No Pressing for 5 seconds return to standby interface if user doesn t want to save every press enter the current trimmer status firstly and cycle...

Страница 6: ...ng users common parameters reset button for restoring users saving parameters before saving factory parameters are the same as users saving parameters P19 P20 version no Parameter P66 P67 P68 the duty...

Страница 7: ...rameter values to change then the P28 parameter is equal to the user saves parameter values 5 When entering the other interface without saving and don t press any key for 5 seconds will automatically...

Страница 8: ...h sensor enabled state changes the sensor will be automatically calibrated 2 16 Thick material voltage threshold setting 1 5 P U15 OK Er P 50 U16 PA2 1 1 5 Press the presser foot lifter for about 1 5...

Страница 9: ...er values of PA0 PA1 Note Normal sewing can be done during regular maintenance reminder 2 19 Short thread mode quick switch 3s OK P27 U25 Press the short thread button for 3 seconds to switch the shor...

Страница 10: ...erized 1 semi automatic 2 fully automatic P6 Voice volume adjustment 0 3 2 0 1 3 0 off 1 3 on P7 Auto trimming 0 3 3 0 1 2 3 0 off 1 trimmer before sewing 2 trimmer after sewing 3 trimmer both before...

Страница 11: ...n 0 250 0 0 100 ms Time when front suction off 0 is not off 100 ms P25 Back sensor switch 0 1 1 0 1 0 off 1 on P Technician parameter At the same time press the P button and the presser foot lifter bu...

Страница 12: ...r foot lifter 1 50 2 100ms P40 Start time after presser foot lifter 0 20 0 100 ms P41 Full output time of presser foot 1 50 10 10 ms P42 Periodic signal of presser foot output 0 50 15 10 ms 5MS Turn o...

Страница 13: ...tage value of the sensor P68 Adjusting gear of sensor for anti cutting the cloth 1 180 The greater the parameter values The greater the voltage value of the sensor P69 Unit number counting 1 50 10 1 S...

Страница 14: ...hread number closing P82 Synchronized suction back suction closed needle number 0 250 0 0 P82 0 Back suction and back trimmer synchronous closing Other when after front suction opening go by P82 threa...

Страница 15: ...Unit month 0 1 500 0 not enable 1 500 reminder time P102 Base enable of thick material 0 1 0 1 1 Automatic acquisition of base value when thickness enters the threshold setting of thick material P112...

Страница 16: ...function is turned off duty cycle decreases from 100 to U28 setting value uniformly in 1 U29 time duty cycle decreases from U28 to U31 setting value uniformly in 2 U29 time and 3 U28 duty cycle is con...

Страница 17: ...e Please try to restore the factory settings or restart the power supply If the above can not be solved please contact the local service provider or dial 4008876858 Pressing the P key or the voice key...

Страница 18: ...solve the problem please contact with the local agent or call 4008876858 E9 Pedal connection abnormal 4008876858 Please check whether the pedal plug is connecting with control box or not or loosening...

Страница 19: ...Voltage foot electromagnet control fault EA1 The ascending count is full P P71 5 Press P to clear or change value to 5 in parameter P71 EA2 The descending count is full P P71 5 Press P to clear or ch...

Страница 20: ...l and panel program to a matching program A 09 White grease regular maintenance warning A 10 Regular cleaning warning 7 Speed controller 1 4 ST4 8 2 Use four pieces ST4 8tapping screw Part No 2 to ins...

Отзывы: