Jack C5 Скачать руководство пользователя страница 14

12 

 

P76 

背光亮度调节参数

 

Backlight brightness 
adjustment parameters   

1 - 3 

 

P77 

内部限速

Internal speed limit   

500-7000 6000 

RPM 

P78 

显示模式

 

Display mode 

0-4 0 

0

:正常缝纫的模式和转向

 

1

:实时显示当前速度

 

2

:前传感器感应电压值

 

3

:后传感器感应电压值

 

4

:第三传感器感应电压值

 

0: Normal sewing mode and turning   
1: Real-time display of current speed   
2: Induced Voltage Value of Front Sensor   
3: Induced Voltage Value of Rear Sensor   
4: Third Sensor Induced Voltage Value   

P79 

恢复出厂设置

 

Restore factory settings   
 

0-1 0 

0

:无操作;

  1

:恢复所有出厂参数;

 

0

No operation; 1

Restore all factory parameters   

P80 

语言种类选择

 

Choice of Language 
Categories 

0-9 0 

0

:中文

  1

:英文

    2

:俄语

  3

:阿语

    4

:土语

      5

葡语

  6

:西语

  7

:印尼

  8

:越南

9

:波兰语

0: 

Chinese 1: English 2: Russian 3: Arabic 4: Turkish 
5: Portuguese 6: Spanish 7: Indonesia 8: Vietnam 9: 
Polish  

P81 

同步吸气,前吸屑关闭针数

Synchronized suction, front 
suction closed needle number   

0 - 250 

0

:前吸屑与前剪线吸气同步关闭

 

其他:前吸屑开启

P81

针数后关闭

 

0

Front suction and front trimmer synchronous 

closing 
Other

when after front suction opening go by P81

thread number closing 

P82 

同步吸气,后吸屑关闭针数

 

Synchronized suction, back 
suction closed needle number 

0 - 250 

0

:后吸屑与后剪线吸气同步关闭

 

其他:后吸屑开启

P82

针数后关闭

 

0

Back suction and back trimmer synchronous 

closing 
Other

when after front suction opening go by P82

thread number closing 

P83 

前剪线松线电磁阀开启针数

Stitch number of front 
trimming loose line solenoid 
valve on 

0 - 50 

0

:前剪线松线电磁阀关闭

 

其他:前剪线松线电磁阀经

(P83)-1

针数开启

 

0:Front trimming loose line solenoid valve opening 
Other:Front trimming loose line solenoid valve go 
by (P83)-1 open thread number 

P84 

前剪线松线电磁阀关闭针数

Stitch number of front 
trimming loose line solenoid 
valve off   

1 - 50 

 

P85 

后剪线松线电磁阀开启针数

 

Stitch number of back 
trimming loose line solenoid 
valve on   

1 - 50 

12 

0

:后剪线松线电磁阀关闭

 

其他:后剪线松线电磁阀经

P85

针数开启

 

0:back trimming loose line solenoid valve off 
Other: back trimming loose line solenoid valve 
open by P85 stitch number 

P86 

b

剪线松线电磁阀关闭针数

 

Stitch number of back 
trimming loose line solenoid 
valve off 

1 - 50 

50 

 

P87 

手动吸气持续时间

(*100ms) 

Duration time of manual 
suction 

1-50 3 

 

P88 

手动吸气电机转速

 

Speed of manual suction motor 

500 – 7000 

3500 

 

P89 

- - 

C3

使用

 used 

P90 

错误查看使能

 

Error viewing enable   

0 - 1 

 

P91 

薄料感应延时滤波延时针数

 

Delay needle number of 

0 - 100 

30 

 

Содержание C5

Страница 1: ...C5 V1 8 Instructions of C5 overlock sewing machine panel operation 2020 6 1 EC5...

Страница 2: ...e Setting 4 2 9 LED light setting 4 2 10 Button lock setting 4 2 11 Voice quick switch 4 2 12 Sensor for anti cutting the cloth swift switch 5 2 13 Forced removal of cloth piece value 5 2 14 Fabric se...

Страница 3: ...ase the number within a parameter 5 Right button control machine head LCD light brightness Towards the right to choose parameter within a parameter 6 Sewing mode button Change the sewing mode 7 Presse...

Страница 4: ...be cycled as following three modes Automatic Semi automatic Full manual Press enter mode to confirm and save after finishing setting No Pressing for 5 seconds return to standby interface if user does...

Страница 5: ...ter button to save and confirm after finishing setting No Pressing for 5 seconds return to standby interface if user doesn t want to save every press enter the current trimmer status firstly and cycle...

Страница 6: ...ng users common parameters reset button for restoring users saving parameters before saving factory parameters are the same as users saving parameters P19 P20 version no Parameter P66 P67 P68 the duty...

Страница 7: ...rameter values to change then the P28 parameter is equal to the user saves parameter values 5 When entering the other interface without saving and don t press any key for 5 seconds will automatically...

Страница 8: ...h sensor enabled state changes the sensor will be automatically calibrated 2 16 Thick material voltage threshold setting 1 5 P U15 OK Er P 50 U16 PA2 1 1 5 Press the presser foot lifter for about 1 5...

Страница 9: ...er values of PA0 PA1 Note Normal sewing can be done during regular maintenance reminder 2 19 Short thread mode quick switch 3s OK P27 U25 Press the short thread button for 3 seconds to switch the shor...

Страница 10: ...erized 1 semi automatic 2 fully automatic P6 Voice volume adjustment 0 3 2 0 1 3 0 off 1 3 on P7 Auto trimming 0 3 3 0 1 2 3 0 off 1 trimmer before sewing 2 trimmer after sewing 3 trimmer both before...

Страница 11: ...n 0 250 0 0 100 ms Time when front suction off 0 is not off 100 ms P25 Back sensor switch 0 1 1 0 1 0 off 1 on P Technician parameter At the same time press the P button and the presser foot lifter bu...

Страница 12: ...r foot lifter 1 50 2 100ms P40 Start time after presser foot lifter 0 20 0 100 ms P41 Full output time of presser foot 1 50 10 10 ms P42 Periodic signal of presser foot output 0 50 15 10 ms 5MS Turn o...

Страница 13: ...tage value of the sensor P68 Adjusting gear of sensor for anti cutting the cloth 1 180 The greater the parameter values The greater the voltage value of the sensor P69 Unit number counting 1 50 10 1 S...

Страница 14: ...hread number closing P82 Synchronized suction back suction closed needle number 0 250 0 0 P82 0 Back suction and back trimmer synchronous closing Other when after front suction opening go by P82 threa...

Страница 15: ...Unit month 0 1 500 0 not enable 1 500 reminder time P102 Base enable of thick material 0 1 0 1 1 Automatic acquisition of base value when thickness enters the threshold setting of thick material P112...

Страница 16: ...function is turned off duty cycle decreases from 100 to U28 setting value uniformly in 1 U29 time duty cycle decreases from U28 to U31 setting value uniformly in 2 U29 time and 3 U28 duty cycle is con...

Страница 17: ...e Please try to restore the factory settings or restart the power supply If the above can not be solved please contact the local service provider or dial 4008876858 Pressing the P key or the voice key...

Страница 18: ...solve the problem please contact with the local agent or call 4008876858 E9 Pedal connection abnormal 4008876858 Please check whether the pedal plug is connecting with control box or not or loosening...

Страница 19: ...Voltage foot electromagnet control fault EA1 The ascending count is full P P71 5 Press P to clear or change value to 5 in parameter P71 EA2 The descending count is full P P71 5 Press P to clear or ch...

Страница 20: ...l and panel program to a matching program A 09 White grease regular maintenance warning A 10 Regular cleaning warning 7 Speed controller 1 4 ST4 8 2 Use four pieces ST4 8tapping screw Part No 2 to ins...

Отзывы: