background image

Alarm system JA-65 MAESTRO 

- 12 - 

MFM53003 

 

11.17. Partial arming exit delay audible indication 

sequence:  3 4 x 

Partial arming with 

 (F2)  provides an exit delay for delayed 

reaction detectors in section A. The exit delay for partial arming 
can be indicated by the „beeping“ of the keypad (for the last five 
seconds the beeping is faster). 

options: 

3 4 1

 indication 

enabled

 

3 4 0

 indication 

disabled

  

Factory default setting: indication disabled 

Note: when this indication is disabled, the  confirmation of 
partial arming and disarming will  automatically be silent, 
regardless of the   36x setting. 

 

11.18. Entrance delay audible indication 

sequence:  3 5 x 

The entrance delay can be indicated by a rapid „beeping“ of the 
keypad. This indication can be disabled with this setting. 

options: 

3 5 1

 indication 

enabled

 

3 5 0

 indication 

disabled

  

Factory default setting: indication enabled 

 

11.19. Arming and disarming chirps with hard wired 
siren  

sequence:  3 6 x 

The control panel can confirm on the SIR output arming (1 
chirp), disarming (2 chirps), disarming with information in the 
memory (3 chirps), bypass or not ready component when arming 
(4 chirps). This parameter sets chirps on. 

options: 

3 6 1

 siren 

chirps 

enabled

 

3 6 0

 siren 

chirps 

disabled

  

Factory default setting: siren chirps disabled 

Note: setting of chirp sounds is valid even if the siren is disabled 
for alarms with parameter 320. Partial arming is always silent, if 
sequence 340 is selected. Chirp sounds can also be generated 
with the JA-60A wireless siren (self-contained setting in the 
wireless siren). 

 

11.20. Siren alarm in Disarm & Partial arming 

sequence:  3 7 x 

The SIR output can be disabled for alarms during the  Disarm & 
Partial arming of the control panel (while somebody is indoors). 
If the siren output is completely disabled for alarms with 
parameter 320, this setting has no effect.  

options: 

3 7 1

 

alarm in disarm & partial arming 

enabled

 

3 7 0

 

alarm in disarm & partial arming 

disabled

  

Factory default setting: enabled 

 

11.21. Wireless siren alarm 

 

sequence:  3 8 x 

The wireless siren alarm function can be disabled with this 
parameter. This setting will have no influence on the outdoor 
wireless siren chirp sound function if enabled in the siren. This 
setting has effect only when the control panel is equipped with a 
65R module: 

options: 

3 8 1

 siren 

enabled

 

3 8 0

 siren 

disabled

  

Factory default setting: siren enabled 

 

11.22. Indication of system problems when arming 

sequence:  3 9 x 

The system regularly checks the conditions of all items 
(detectors, keypads etc.). This setting ensures that the user will 
be warned with 4 rapid beeps after arming, if any component of 
the system is not ready for arming. Cause of the problem (for 
example permanently triggered detector, lost communication 
etc.) will remain displayed on the keypad. If the user ignores this 
warning, the system will arm after the exit delay, then an alarm 
will be triggered and finally the problematic item will be 
bypassed for this arming period. After disarming in such a mode, 
three beeps will be generated as well.  
When the indication is not selected, the problematic item will be 
bypassed when arming with neither warning nor alarm. 

If a permanently activated detector is deactivated during arming 
(for example your main door is not closed), the bypass of this 
detector will be canceled automatically and the detector will be 
ready to trigger an alarm after it is activated (if you close the 
door after the system is armed).    

 

options: 

3 9 1

 warning 

enabled

 

3 9 0

 warning 

disabled

  

Factory default setting: warning disabled 

Note: if this indication is enabled, the problems will also be 

indicated if there are any when leaving the 
programming or user mode. 

 

 

11.23. Control panel splitting   

sequence:  690 x    

The control panel can be split in to 2 independent sections A 
and B, with a shared common area C. This way the system can 
be operated by two independent user groups. In fact the system 
in this mode works like two independent systems. If the system 
is split to the sections with this setting, it is possible to address 
detectors (both wireless and wired), user codes and remote 
controls to the above sections (see 11.2., 11.31 and 11.32.). 

options: 

6 9 0 0

 

no splitting

 (partial arming available in this mode) 

6 9 0 1

 

splitting to sections A, B and common C

  (C is 

armed only when both A and B are armed)  

Factory default setting: no splitting 

 
 

11.24. Only first source of alarm is recorded 

sequence:  691 x  

When any item triggers the alarm 4 times in a row the system 
will bypass it until any other events occurs.  But it is possible to 
set the limit at the incoming events so only the very first event 
during the entire alarm will be recorded. This function is useful 
especially if the system contains a GSM communicator in order 
to decrease quantity of the SMS messages. This setting is valid 
for all kinds of the alarm.   

Options:  

6 9 1 0

 

All sources

 of alarm are recorded 

6 9 1 1

 

Only first source

 of alarm is recorded 

Factory default setting: All sources of alarm are recorded

 

 

11.25. Alarm triggered by opened zone when arming 

sequence:  692 x    

If the “indication of system problems when arming” (see 11.22) 
is enabled, it is also possible to test the status of the detectors 
after expiring the exit delay. If any item is activated then in case 
of instant zone the alarm will be triggered immediately, in case 
of delay zone the entry delay will start.  

Содержание MAESTRO JA-65

Страница 1: ...JA 65 MAESTRO Alarm system installation manual...

Страница 2: ......

Страница 3: ...audible indication 12 11 19 Arming and disarming chirps with hard wired siren 12 11 20 Siren alarm in Disarm Partial arming 12 11 21 Wireless siren alarm 12 11 22 Indication of system problems when a...

Страница 4: ...ireless output modules Hard wired input module JA 65H has 8 input loops with programmable triggering NC balanced or double balanced and programmable reactions Up to two JA 65H hard wired input modules...

Страница 5: ...e should be connected to the metal case Instructions use flexible 2 core size from 0 75 to 1 5 mm 2 double insulated power cord The system should not share a fuse 10 A max with any other household ite...

Страница 6: ...nal siren output In the normal mode it has the U terminal voltage In the alarm mode it has a GND terminal potential Connect an ordinary external siren to U and SIR terminals max load 0 7 A A back up s...

Страница 7: ...ed backup period a 12V back up battery from 1 3Ah to 45Ah can be used instead A battery larger than 7Ah must be installed in an external case and the case must be equipped with tamper protection The c...

Страница 8: ...module only No code requested effects F4 F8 F9 30x 301 YES 300 NO YES Partial Home arming enabled 31x 311 YES 310 NO YES Siren alarm enabled 32x 321 YES 320 NO YES Exit delay audible indication enabl...

Страница 9: ...its enrollment signal The siren will send the signal only if it has no current communication with any other control panel This protects you from enrolling your neighbor s siren Enrollment is complete...

Страница 10: ...ice message and telephone numbers of the built in dialer If the changes are enabled then programming sequences for number programming voice message recording and dialer testing are accessible in the U...

Страница 11: ...panel was enrolled to position c3 scroll to this position in the enrolling mode and holding key 2 will erase the master control panel as a controller 11 12 Enrollment of the control panel to a UC 2xx...

Страница 12: ...s after arming if any component of the system is not ready for arming Cause of the problem for example permanently triggered detector lost communication etc will remain displayed on the keypad If the...

Страница 13: ...en to enter the programming mode SC 6060 MC 1234 must be set F0 6060 1234 Factory default setting disabled Note it has no influence on the user mode entering F0 MC 11 30 Addressing of wireless detecto...

Страница 14: ...ed wireless controller or siren signal receiving will be similarly indicated Some detectors JA 60P JA 60N JA 60B etc have an extra testing mode which is usually activated for 5 minutes after the detec...

Страница 15: ...amples There is a comprehensive help file in the Comlink program virtual control panel access complete events list item testing window RF signal oscilloscope programming dialogs map of the system show...

Страница 16: ...distributor for advice local hot line number 17 Possibilities to extend the system The JA 65 alarm system is a kit which can be tailor configured according to the size of the house or the needs of th...

Страница 17: ...e outputs PgX PgY Chime Fire Arm Panic Alarm Door Home AC failure Phone siren output 12 V 0 7 A Wireless outputs module 65R transmits signals for siren and PgX PgY data for UC 2xx receivers Events mem...

Отзывы: