Alarm system JA-65 MAESTRO 

- 17 - 

MFM53003 

 

 

18. Control panel specifications: 

 

Electrical

 

Power  

230 VAC, max 0.35 A, (built in electronic power supply), supervised, protection class II 

Backup battery  

12 V, from 1.3 to 7 Ah (external up to 40 Ah), supervised, not included 

Backup power output for wired items  13VDC, the max. permanent current is 0.7 or 1.2 A for max. 15 min (not more then one cycle 

per hour) 

 

 

Hard-wired inputs

  

module 65H: 8 input zones, up to two  65H  modules  can be used (16 zones) 

Zone input triggering 

selectable: NC, End Of Line resistor or Double End Of Line resistor 

Zone reaction 

selectable: instant, delayed, panic, fire, 24 hour, next delayed, control 

Modules stand-by consumption 

K=10 mA, H=15 mA, X=12 mA, GSM=50 mA, keypad JA-60E=25 mA

 

 

 

Wireless communication 

module 65R: up to 16 detectors (JA-60), 8 controllers, 1 outdoor siren JA-60A, subsystem 

Working frequency 

433.92 MHz; digital hopping code; supervised communication 

 

 

Keypads 

max. 5 wired JA-60E keypads, max. 8 JA-60F  wireless keypads or RC-40 or JA-60D remote 
controllers  

Access codes 

master code and 14 user codes. When system is split, codes, detectors and remote controls 
can be addressed to particular sectors 

 

 

Wired outputs 

Alarm relay dry contacts 1A/60V; programmable outputs PgX & PgY (Chime, Fire, Arm, 
Panic, Alarm, Door, Home, AC failure, Phone), siren output (12 V, 0.7 A) 

Wireless outputs 

module 65R transmits signals for siren and  PgX, PgY data for UC-2xx receivers 

Events memory 

127 most recent events including date, time and detailed specification 

 

 

 
Environmental

 

Operating temperature  

-10°C to 40° C 

Operating humidity  

max 80 % 

Working environment 

indoor use (class II, EN 50131-1) 

 

Electronic design

 

Design 

SMT; modular system (radio module 65R, hardwired zones module 65H, telephone communicator module 
65X); full supervision; monitoring of RF jamming 

Electrostatic discharge 

8 kV 

RF immunity  

 

30 V / m 

 

Physical

 

Housing  

 

metal box with built-in electronic power supply 

Dimensions 

 

295 x 280 x 90mm 

Shipping weight    

2.72kg 

Color 

 

 

white or light gray 

 

Standards

 

Complies with: EN 50131-1 (Grade 2), EN 50131-6, EN 300220, ETS 300 683, EN 50136, ETS 300001, TBR 21 

 

** can be operated according to ERC REC 70-03 

 

Hereby, Jablotron Ltd., declares that this JA-65  is in compliance with the essential requirements and other relevant 
provisions of Directive 1999/5/EC.

 Original  of the conformity assessment can be found at the web page www.jablotron.com, 

section Technical support. 

 
Note:
 Dispose of batteries safely depending on the type of the batteries and local regulation. Although this product does not contain any harmful 
materials we suggest you to return the product to the dealer or directly to the producer after usage.

 

Содержание MAESTRO JA-65

Страница 1: ...JA 65 MAESTRO Alarm system installation manual...

Страница 2: ......

Страница 3: ...audible indication 12 11 19 Arming and disarming chirps with hard wired siren 12 11 20 Siren alarm in Disarm Partial arming 12 11 21 Wireless siren alarm 12 11 22 Indication of system problems when a...

Страница 4: ...ireless output modules Hard wired input module JA 65H has 8 input loops with programmable triggering NC balanced or double balanced and programmable reactions Up to two JA 65H hard wired input modules...

Страница 5: ...e should be connected to the metal case Instructions use flexible 2 core size from 0 75 to 1 5 mm 2 double insulated power cord The system should not share a fuse 10 A max with any other household ite...

Страница 6: ...nal siren output In the normal mode it has the U terminal voltage In the alarm mode it has a GND terminal potential Connect an ordinary external siren to U and SIR terminals max load 0 7 A A back up s...

Страница 7: ...ed backup period a 12V back up battery from 1 3Ah to 45Ah can be used instead A battery larger than 7Ah must be installed in an external case and the case must be equipped with tamper protection The c...

Страница 8: ...module only No code requested effects F4 F8 F9 30x 301 YES 300 NO YES Partial Home arming enabled 31x 311 YES 310 NO YES Siren alarm enabled 32x 321 YES 320 NO YES Exit delay audible indication enabl...

Страница 9: ...its enrollment signal The siren will send the signal only if it has no current communication with any other control panel This protects you from enrolling your neighbor s siren Enrollment is complete...

Страница 10: ...ice message and telephone numbers of the built in dialer If the changes are enabled then programming sequences for number programming voice message recording and dialer testing are accessible in the U...

Страница 11: ...panel was enrolled to position c3 scroll to this position in the enrolling mode and holding key 2 will erase the master control panel as a controller 11 12 Enrollment of the control panel to a UC 2xx...

Страница 12: ...s after arming if any component of the system is not ready for arming Cause of the problem for example permanently triggered detector lost communication etc will remain displayed on the keypad If the...

Страница 13: ...en to enter the programming mode SC 6060 MC 1234 must be set F0 6060 1234 Factory default setting disabled Note it has no influence on the user mode entering F0 MC 11 30 Addressing of wireless detecto...

Страница 14: ...ed wireless controller or siren signal receiving will be similarly indicated Some detectors JA 60P JA 60N JA 60B etc have an extra testing mode which is usually activated for 5 minutes after the detec...

Страница 15: ...amples There is a comprehensive help file in the Comlink program virtual control panel access complete events list item testing window RF signal oscilloscope programming dialogs map of the system show...

Страница 16: ...distributor for advice local hot line number 17 Possibilities to extend the system The JA 65 alarm system is a kit which can be tailor configured according to the size of the house or the needs of th...

Страница 17: ...e outputs PgX PgY Chime Fire Arm Panic Alarm Door Home AC failure Phone siren output 12 V 0 7 A Wireless outputs module 65R transmits signals for siren and PgX PgY data for UC 2xx receivers Events mem...

Отзывы: