The JA-82Y GSM communicator installers manual
13/13
MDL51109
Tab. 7 communicator programming sequence continues
Function
Sequence
Possible options
Factory default settings
ARC main telephone number / IP address
/ URL
01 p xx..x
0
p=1 ARC1, p=2 ARC2, p=3 IMG, xx..x = tel.
number max. 30 digits. When using IP protocol, IP
or URL addresses are entered instead of
telephone numbers
– see URL command
To erase the corresponding telephone numbers or
URL addresses enter 01p*0
erased
ARC backup telephone number / IP
address / URL
02 p xx..x
0
p=1 ARC1, p=2 ARC2, p=3 IMG, xx..x = tel.
number max. 30 digits. When using IP protocol, IP
or URL addresses are entered instead of
telephone numbers
– see URL command
To erase the corresponding telephone numbers or
URL addresses enter 02p*0
erased
Main ARC URL address setting
See ARC main telephone number / IP address / URL
Performed via OLink software or by SMS instruction
code
URL p xxxxxxx : pppp
where p=1 ARC1, p=2 ARC2, p=3 IMG, xx..x =
URL address, pppp = port address (not required).. SMS instruction example:
URL 1
www.arc1.com
: 08080
To erase the
addresses key in 01p
0, 02p
0 or ARC telephone number
Installation (alarm system) ID for ARC use
03 p zz..z
0
p=1 ARC1, p=2 ARC2, p=3 IMG, xx..x =
installation number max. 8 characters 0 to 9 and
1=A to
6=F
0000
Selecting
the
ARC
communication
protocol
04 p x
p=1 ARC1, p=2 ARC2, p=3 ARC3(IMG)
x=0 CID,
x=1 Jablotron IP,
x=2 Jablotron SMS,
x=5 IMG
– Jablotron image server
1 Jablotron IP
2 Jablotron SMS
Selection of events to report to ARCs
05 p uu x
p=1 ARC1, p=2 ARC2
uu is an event code (see 7.4)
x=1 report, x=0 no report
All events are reported - see tab. 3
Periodic or fixed ARC connection check
06 p x
p=1 ARC1, p=2 ARC2
x=0 with a period from the last report according to
the 07 p hhmm setting
x=1 once a day at the time set by entering 07 p
hhmm
With a period after the last report (X=0)
ARC communication checking period
07 p hhmm
p=1 ARC1, p=2 ARC2
hhmm = hours, minutes, see setting via 06 p x
2359
Enable ARC reporting (ARC2 backs up
ARC1)
08 p x
p=1 ARC1, p=2 ARC2
x=0 reports disabled, x=1 reports enabled,
x=2 only for ARC1, sets that ARC2 backs up
ARC1
1,2 ARC reporting disabled
3 enabled (IMG)
Recording reports sent to ARCs in the
control panel memory
001 x
x=0 no (only records ARC communication faults)
x=1 yes (all reports except communication checks)
no
Indicate an ARC communication fault if a
report is not successfully received within
110 sec of transmission
002 x
x=0 no
x=1 yes
no
Remote access password
894 xxx …x
0
1-32 characters, (only numbers are available when
using keypad)
1234ABCD
Locking the ARC settings
091 xx..x
0
xx..x is your code (4 to 8 digits)
Entering this code and then exiting service mode
will lock the ARC settings
091*0 will erase the code (permanently unlocked)
unlocked
Unlocking the ARC settings
092 xx..x
0
xx..x is the locking code used by sequence 091
ARC programming can be temporarily enabled in
service mode by entering this sequence. It will then
relock on exiting service mode. For permanent
unlocking see sequence 091.
Period of waiting before repeating
unsuccessful communication to the ARC
0001 p mmss
p=1 ARC1, p=2 ARC2
mmss = minutes, seconds
0015
Number of repeated attempts after
unsuccessful communication to the ARC
0002 p n
p=1 ARC1, p=2 ARC2
n= 1x to 9x
2x