The JA-82Y GSM communicator installers manual
11/13
MDL51109
12. Summary of all communicator texts for SMS messages and instructions
n
factory default text:
n
factory default text:
n
factory default text:
0
Your system is reporting:
502
Delayed loop alarm
549
Master code changed
1
Device
503
Fire
550
The message has been transmitted by the
communicator.
2
Device
504
Panic alarm
551
Message transmission failed
.
…
505
Searching for a code
552
Service request
.
…
506
Alarm after powering up the system
553
PgX output ON
50
Device
507
Tamper alarm
554
PgX output OFF
201
Control panel
508
End of temper alarm
555
PgY output ON
202
Service code
509
End of alarm indication
556
PgY output OFF
203
Service inspection request
510
Alarm cancelled by user
601
SET
204
Communicator
511
Setting
602
UNSET
205
Keypad
512
Unsetting
603
STATUS
206
ARC code
514
Codeless setting
604
MEMORY
300
Master code
515
External communication fault
605
PGX ON
301
Code
516
External communication restored
606
PGX OFF
302
Code
517
Fault
607
PGY ON
.
…
518
Fault removed
608
PGY OFF
.
…
519
Mains dropout over 30 minutes
611
CREDIT
350
Code
520
Mains dropout
612
TXT
400
System status:
521
Mains recovery
613
PRG
401
Set
522
Battery discharged
614
GPRS
402
Unset
523
Battery OK
615
GSM
403
Exit delay
524
Switching to service mode
616
URL
404
Entrance delay
525
Leaving service mode
701
Enrolling
405
Alarm:
528
Radio jamming present
702
Finish setting
406
Service mode
529
Internal communication error
703
Signal strength
407
Maintenance mode
530
Internal communication restored
704
Control
409
Battery discharged
531
Communication test
705
Bypass
410
Tamper alarm
532
Unconfirmed alarm
706
Test OK
411
Alarm memory
533
Blocking after an alarm
707
Test error
412
Fault
534
Unblocking after an alarm
708
0/4
413
Power supply fault
535
Partial setting A
709
1/4
414
Unknown device status
536
Partial setting B
710
2/4
415
Time:
537
Partial setting AB
711
3/4
416
Last event:
538
Partial unsetting A
712
4/4
417
Unknown credit
539
Partial unsetting B
713
Code
418
Credit
540
Communicator failure
714
Text modification
420
Error while processing command
541
Communicator OK
715
Current detector
421
Output ON
542
Control panel battery failure
716
Service inspection
422
Output OFF
543
Control panel battery OK
717
Active output
423
Partially set A
544
Alarm 24h
718
Active detectors
424
Partially set B
545
Low credit balance
720
OASIS JA-80
425
Partially set AB
546
Power supply ON
721
Codes
426
SMS instruction processed successfully
547
Control panel reset
501
Instant loop alarm
548
Master code reset to 1234
tab. 6 table of factory-default SMS report and instruction texts
Notes:
The communicator always automatically puts numbers from 01 to 50 in front of Device or Code names
Texts
0 to 556
are used to create SMS
event reports
Texts
601 to 616
are SMS instructions (to control the system remotely by SMS)
Texts
700 to 721
are used by keypads
Other texts are part of system configuration and are set in the OLink application