The JA-82Y GSM communicator installers manual
10/13
MDL51109
11. List of events which can be reported to your phone and their factory default settings
uu
Event
Telephone number memory - M
ABC
AC
BC
ABC
1
2
3
4
5
6
7
8
Voice message
00
Alarm after powering up the system
SC
SC
SC
S
SC
SC
S
5: “fault“
01
Instant loop alarm
SC
SC
SC
S
SC
SC
S
1: “intruder alarm“
02
Delayed loop alarm
SC
SC
SC
S
SC
SC
S
1: “intruder alarm“
03
Fire alarm
SC
SC
SC
S
SC
SC
S
2: “fire alarm“
04
Panic alarm
SC
SC
SC
S
SC
SC
S
4: “panic alarm“
05
Tamper alarm
SC
SC
SC
S
SC
SC
S
3: “tamper alarm”
06
Number of permitted incorrect code-entries exceeded
SC
SC
SC
S
SC
SC
S
3: “tamper alarm”
07
Device fault
S
S
5: “fault“
08
Complete setting
”Armed system“
09
Complete unsetting
”Disarmed system“
12
Codeless setting
”Armed system“
13
Partial setting A
”Partially armed“
14
Detector communication failure
5: “fault“
15
Control panel power supply dropout
7: “other event“
16
Control panel power supply restored
7: “other event“
17
Detector power supply dropout
S
S
5: “fault“
18
Communicator failure
S
S
5: “fault“
19
Communicator OK
7: “other event“
20
Control panel battery failure
S
S
5: “fault“
21
Control panel battery OK
7: “other event“
23
Alarm 24h
SC
SC
SC
S
SC
SC
S
1: “intruder alarm“
24
Receiver jamming
5: “fault“
26
Setting A
– split system
”Armed system“
27
Setting B
– split system
”Armed system“
28
Unsetting A
– split system
”Disarmed system“
29
Unsetting B
– split system
”Disarmed system“
33
Partial setting AB
”Partially armed“
50
Low SIM card credit balance
S
5: “fault“
51
Image delivered to server (e.g. from JA-84P)
S
7: “other event“
64
Power supply ON
7
: “other event“
65
Switching to service / maintenance mode
7: “other event“
66
Exiting service / maintenance mode
7: “other event“
67
End of alarm indication
7: “other event“
78
Alarm cancelled by user
S
S
S
S
S
S
S
7: “other event“
79
Control panel reset
7: “other event“
80
All tampers on standby
7: “other event“
81
All faults removed
7: “other event“
82
System power supply OK
7: “other event“
83
The communicator has no connection
5: “fault“
84
Communicator connection restored
7: “other event“
85
Master code reset to 1234
7: “other event“
86
Master code changed
7: “other event“
68
Reporting to ARC1
7: “other event“
69
No reporting to ARC1
5: “fault“
89
Power supply failure exceeding 30 minutes
S
5: “fault“
90
Unconfirmed alarm
7: “other event“
91
Service request
7: “other event“
92
PgX output ON
7: “other event“
93
PgX output OFF
7: “other event“
94
PgY output ON
7: “other event“
95
PgY output OFF
7: “other event“
96
Blocking after an alarm (Engineer reset)
7: “other event“
97
Unblocking after an alarm
7: “other event“
tab. 5 List of events which can be reported to your phone and their factory default settings
Notes:
Factory default report assignment: S = SMS, C = call, SC = SMS followed by a call
“External communication fault“ means a GSM network dropout longer than 15 minutes (if GSM network dropout indication is enabled)
To get an SMS (from the JA-84P) with a picture link, enable event 51
In a split system it is necessary to synchronize the current control panel settings by opening enrollment mode for 1 s and closing it before you leave service mode
In a split system telephone memory positions are associated with certain sections for reporting alarms as below:
o
1st telephone number: sections A, B, C (administrator/master)
o
2nd to 4th telephone numbers: sections A, C
o
5th to 7th telephone numbers: sections B, C
o
8th telephone number sections: A, B, C (service technician)