LED displays
Copyright IXXAT Automation GmbH
9
CANio 500 Quickstart Manual, version 1.3
2.4
Connector (X4) analog
The analog signals are available on connector X4. Connector X4 is designed
as a 15-pin high density D-Sub HDM15 (pins, male) (see table 2-4).
The functions of the analog inputs and outputs are described in chapters 4.5
and 4.6.
Pin no. X4 Signals
Description
1
ANA_IN1_P
Analog input 1 positive (+)
2
ANA_IN2_P
Analog input 2 positive (+)
3
GNDA
Analog ground
4
ANA_IN3_P
Analog input 3 positive (+)
5
ANA_IN4_P
Analog input 4 positive (+)
6
ANA_IN1_M
Analog input 1 negative (-)
7
ANA_IN2_M
Analog input 2 negative (-)
8
GNDA
Analog ground
9
ANA_IN3_M
Analog input 3 negative (-)
10
ANA_IN4_M
Analog input 4 negative (-)
11
ANA_OUT1
Analog output 1
12
ANA_OUT2
Analog output 2
13
GNDA
Analog ground
14
ANA_OUT3
Analog output 3
15
ANA_OUT4
Analog output 4
Table 2-4: Pin assignment analog interface connector D-Sub HDM15
3 LED displays
The CANio 500 has four two-colored LEDs (see Figure 2-1). The LEDs react
as follows according to the operating mode of the CANio 500.
3.1
PWR - LED
The Power-LED (PWR) is lit green when the CANio 500 is connected to the
power supply. The Power-LED (PWR) is lit red when the power supply is con-
nected with reverse polarity.