Software
Copyright IXXAT Automation GmbH
28
CANio 500 Quickstart Manual, version 1.3
The CANio 500 does not communicate with the
CAN bus during this initialization.
After being initialized, it will announce itself with
the
Bootup
message at the CAN bus.
It will be in the state „operational“
Else
Not defined
Will be ignored
Description of the Reset:
The CANio 500 is being initialized completely. In case that a configuration has
been stored, the CANio 500 will be initialized with this configuration. In case
that no configuration has been stored, or a stored one has been declared inva-
lid, the CANio 500 will be initialized with the default values (see 5.1.13).
The digital and analog outputs will be initialized with their
“configured” default
values.
Description of the limited Reset:
In case of the restricted Reset, the I/O functionality will not be initialized:
The configuration of the digital and analog inputs and outputs is not
changed.
The digital and analog outputs are not changed.
The parameters of the CAN messages the CANio 500 is using are initialized:
CAN identifiers
Event Timer of the CAN messages
Inhibit Time of the CAN messages
After a configuration has been stored, these objects are initialized with the
stored configuration. In case that no configuration has been stored, or a stored
one has been declared invalid, the CANio 500 will be initialized with the default
values (see 5.1.13).