Software
Copyright IXXAT Automation GmbH
18
CANio 500 Quickstart Manual, version 1.3
Factory settings of the analog outputs:
1
The default analog output range is defined by the HW variant of the
CANio 500 (see Info in 5.1.5)
:
Range of the analog inputs
Range of the analog outputs
0 - 10 V
0 - 10 V
+/- 5 V
+/- 5 V
+/- 100 mA
+/- 10 V
After power on every output is initialized with 0 V.
5.1.6 Digital inputs
The CANio 500 transmits the values of the digital inputs 1-4 with the following
CAN message:
CAN identifier
Data field (length = 2)
Byte 0
Byte 1
0x180 + node number of the
CANio 500
Saved configuration
:
saved identifier
Values of the digital
inputs 1-4
Additional digital input
and HW info
Assignment of byte 0:
Bit number
Meaning
0
Value of digital input 1
1
Value of digital input 2
2
Value of digital input 3
3
Value of digital input 4
4 - 7
not relevant
1
In case that no configuration has been saved or the saved configuration was declared as invalid, the
analog outputs are initialized with these factory settings.