CANio 500 Quickstart Manual, version 1.3
5.1
CANio 500 as a CAN module
5.1.1 CAN
– Identifier
The CANio 500 supports CAN identifier with 11 bits.
5.1.2 CAN baudrate
As default, the CANio500 is delivered with the CAN baudrate 250kBit/s.
5.1.3 Node number
As default, the CANio 500 is delivered with node number 10d (0x0A). This in-
formation is requisite to determine the CAN identifiers of its transmit and re-
ceive messages respectively.
5.1.4 Setting the digital outputs
The digital outputs of the CANio 500 are controlled with the following CAN
message:
CAN identifier
Data field (length = 2)
Byte 0
Byte 1
0x200 + node number of the
CANio 500
Saved configuration
:
saved identifier
Digital outputs 1-4
digital outputs to con-
trol the USR 1/2 LEDs
Assignment of byte 0:
Bit number
Meaning
0
Value of digital output 1
1
Value of digital output 2
2
Value of digital output 3
3
Value of digital output 4
4 - 7